In this case, the setting value of zone 1 is T1S, the setting value of zone 2 is T1S2 (the corresponding T1S2 is calculated
based on the climatic curves).
10.5.6
Room thermostat.
Information on Room
e ROOM THERMOSTAT setting is used if the room thermostat is available.
How to set the Room
Go to MENU>FOR SERVICEMAN>6. ROOM THERMOSTAT.
Press OK.
e following page will be displayed:
NOTE
ROOM THERMOSTAT = MODE SETTING, wiring of the room thermostat must follow method A.
ROOM THERMOSTAT = ONE ZONE, wiring of the room thermostat must follow method B.
ROOM THERMOSTAT = DOUBLE ZONE, wiring of the room thermostat must follow method C
(see 9.7.6 Connection for other components/For the room thermostat).
7
Other Heating Source.
e OTHER HEATING SOURCE is used to set the parameters of the indoor unit backup heater (IBH).
Go to MENU>FOR SERVICEMAN>7. OTHER HEATING SOURCE.
Press OK.
e following page will be displayed:
Homepage (zona 1)
ermostat.
ermostat.
6 TERMOSTATO AMB.
6.1 TERMOSTATO AMB.
MODIFICA
= NO, no room thermostat.
7 ALTRA FONTE RISCALDAMENTO
7.1 dT1_IBH_ON
7.2 t_IBH_DELAY
7.3 T4_IBH_ON
7.4 dT1_AHS_ON
7.5 t_AHS_DELAY
MODIFICA
7 ALTRA FONTE RISCALDAMENTO
7.6 T4_AHS_ON
7.7 POSIZ. IBH
7.8 P_IBH1
7.9 P_IBH2
7.10 P_TBH
MODIFICA
2
Pagina aggiuntiva (zona 2)
(La doppia zona è efficace)
NO
NO
1/2
5°C
30MIN
-5°C
Non utilizzato
Non utilizzato
2/2
Non utilizzato
ANEL.TUBO
0,0kW
0,0kW
2,0kW