e warning signal is indicated by the LED display.
e fault warning LED and the SSM relay do not respond.
e pump keeps running with a limited output.
e faulty operating status indicated must not occur for a long period of time.
Fault
E07
Generator operation
E11
Dry operation
E21*
Overload
(*): Also fault signal E21.
NOTE
centre or representative.
• To guarantee the life expectancy of the pump, it is recommended to have the unit operate at least once every 2 weeks
(make sure that the pump works) or to keep it on for a long period of time (in standby status at start up, the unit will
operate the pump for 1 minute every 24 hours).
ON FIELD SETTINGS.
e unit must be con gured based on the installation environment (outside weather, installed options, etc.) and on the
request of the user. Several settings are available.
SERVICEMAN" on the control panel.
Switching on the unit.
While the unit is switching on, "1%-99%" is displayed on the control panel during initialisation.
be used as long as this process is underway.
Procedure.
To edit one or more settings, proceed as follows.
NOTE
Cause
A uid is owing through the hydraulic
system of the pump
Air in pump
Motor slow, the pump is operated
outside of its speci cations (e.g. high
temperature of the module).
is lower than normal operation.
ese settings can be accessed and programmed from the section "FOR
°C.
MENU
• Go to main menu
ove the cursor on the display
• Move inside the menu
• Adjust the settings
• Activate/deactivate the space heating/cooling operation or DHW
mode
ON/OFF
• Activate or deactivate the functions inside the menu
BACK
• Go back to higher level
• Long press to unlock/lock the control panel
UNLOCK
• Unlock/lock some functions such as "DHW temperature adjust-
ment"
• Go to the next step when programming a schedule in the menu;
OK
• Con rm a selection to access a submenu
e cause must be eliminated.
Remedy
Check the system
Check the volume/pressure of the water
Check the environmental conditions
e speed
Function
e control panel cannot