Description Of The Display Screen; Display - Firmware Revision - Immergas System Manager Kit Instructions And Warnings

Electronic control
Hide thumbs Also See for System Manager Kit:
Table of Contents

Advertisement

The button (Ref. 2 Fig. 1-1) allows you to access the
submenus:
- Selection menu for room comfort and reduced Set Point;
- Programming menu for clock and time periods (4 daily
on-off time periods for the comfort temperature);
- "Info" menu, to view the "System Manager Kit" input
data (ex. external temperature, flow temperature, set
flow temperature, DHW temperature, solar storage
tank probe temperature);
- Alarms records;
- Assistance menu.
The button (Ref. 3 Fig. 1-1) allows you to move back from
a current menu to the previous one.
The buttons (Ref. 4 and 5 Fig. 1-1) are used to cyclically
scroll through the menus on the display. On the main
screen they allow you to view:
- "Set DHW";
- "Set room and flow zone 1";
- "Set room and flow zone 2";
- "Set room and flow zone 3";
- "Set room and flow zone 4";
- "Set room and flow zone 5";
- "Set room and flow zone 6";
- "Set room and flow zone 7";
- "Set room and flow zone 8";
- "Set room and flow zone HT";
While the "DHW Set", "Room Set", "Flow Set" are dis-
played, press the button (Ref. 6 Fig. 1-1) to access and
edit the displayed data; when the "Room Set" is changed
the device will switch to manual operation until the
controlled status change of the first time range in the
"automatic" condition. When a variation is made to
"Set DHW" or "Set flow" only the relative values will be
changed; a variation made to "Set flow", if an external
probe is being used, will be read by the supervisor as
an offset compared to the value determined by the set
curve. The set flow being sent to the heat pump and/or
integration boiler will have a value of the maximum set
value of ± 15°C.
If anomalies arise, from the heat pump, the current
anomaly will appear on the screen and the possibility of
verifying it in the alarms records menu. Within this menu
it is possible to reset the alarms records or send the reset
command to the machine (see Par. 4.2), it is possible to
send a maximum of 3 consecutive restore commands;
at the end of the three tries a new restore request will be
provided after one hour.
1.2
DESCRIPTION OF THE DISPLAY
SCREEN.
Winter - dhw heating and room central heating
functions are enabled;
Summer - only the dhw heating function is
enabled;
Comfort temperature is active;
Operating with energy savings programme
(reduced);
Operating with automatic program;
Operating with manual program;
Operating with holiday timer program;
Symbol indicating anomaly;
Room central heating request in progress;
Request for dhw in progress;
Summer with cooling - dhw heating and room
cooling functions are enabled;
Operating in "party" mode;
Request to heat or cool room;
Solar panel operation in progress;
System in stand-by;
Request for room cooling in progress;
Dehumidifier with neutral air
Dehumidifier with cooled air
Post-circulation in progress
N.B.: some icons can assume different meanings ac-
cording to the context, see the following paragraphs to
identify the functions activated by the presence of several
icons at the same time.
1.3

DISPLAY - FIRMWARE REVISION

The functions and menus described in this manual refer
to firmware with revision 12.1.
8 8

Advertisement

Table of Contents
loading

Table of Contents