8.1.3 Magis Combo V2 configuration

Parameter T02 and the parameter families UXX, RXX,
IXX are automatically set by the system operator.
Required settings on the indoor unit panel:
- A12 = OFF;
- A13 = 1;
- A21 = 11;
- A22 = OFF;
Refer to the Magis Combo instruction manual to select
the size of the generator.
The range for integration and precedence times are
reduced to:
- 10 - 240 minutes
If optional external probe, connected to Magis Combo
is used:
- connect the optional external probe to Magis Combo.
- Select R01 = IU.
- Disconnect and reconnect power supply from the
device.
You can choose the application type of Magis Combo
(P32):
- Type A;
- Type B.

8.1.4 Magis M configuration

For correct operation of the System Manager with
Magis M, it is ALWAYS necessary to install the Magis
M hybrid system coupling resistor (supplied as stand-
ard with Magis M), as shown in the wiring diagrams
in Chapter 9.
Most of the parameters required for the correct operation
of Magis M are set automatically by the System Manager.
It is suggested to reset the factory settings on Magis M
before configuring the control panel for operation with
the System Manager.
The following configurations are the responsibility of
the installer:
- 1.5 = NO;
- 13.1 = YES;
- 13.2 = YES;
- 15.4 = NO;
- 15.8 = NO;
- 15.10 = NO;
- 17.1 = MAIN.;
Machine
Heat pump 1
- 17.2 =
Heat pump 2
Heat pump 3
Heat pump 4
- 17.3 = 2.
Magis M and its connecting circuit cannot be deaerated
via the deaeration function of the System Manager. Refer
to the Magis M instruction manual for the deaeration
operation.
The Magis M Control Panel, when the unit is combined
with the System Manager, assumes a Gateway role only.
The data displayed may not be real and some configura-
tions or functionalities may generate incompatibilities
and lead to machine downtime.
It is recommended that the Control Panel be installed
in an area not subject to accidental interaction and that
the 'Child Lock' function on the Magis M control panel
be fully enabled. Refer to the control panel booklet sup-
plied with the Magis M for a list of machine functions
that should not be activated in conjunction with the
System Manager.