Notes For Devices For Zones; Notes For Zone Control - Immergas System Manager Kit Instructions And Warnings

Electronic control
Hide thumbs Also See for System Manager Kit:
Table of Contents

Advertisement

7
NOTES FOR DEVICES
FOR ZONES
7.1

NOTES FOR ZONE CONTROL

POWER
MODE
Mode
HUM
SLEEP
CLOCK
TEMP
N.B.: The zone controls must be configured so that
they work correctly with the system manager, and the
address in particular must be set up using the following
procedure:
1 - press the UP key;
2 - within three seconds press the DOWN key;
3 - when the term "PAr" appears on the main area, re-
lease the DOWN key keeping the UP key down and
press the TEMP key within three seconds.
7-1
135
Procedure to change parameters
In this mode, all symbols are shut off, except for the
following fields:
888
indicates the value of the parameter currently
being changed;
88:88
indicates the name of the parameter currently
being changed.
To set the parameters proceed as follows:
1 -The field
88:88
is flashing. Select the parameter you
need to change using the UP/DOWN keys, then press
TEMP.
2 -The field
88:88
is flashing. Set the desired value using
the UP/DOWN keys, then press TEMP.
3 -Repeat the actions from point 1 to complete all of the
desired operations.
4 -To exit parameter change and save the changes that
30
have been made, simply keep TEMP pressed down
for 3 seconds.
To exit parameter change without saving the changes that
have been made, simply wait 60 seconds after pressing
the last key, or press SLEEP. 45 seconds after pressing the
last key the name of the parameter or the numerical value
will flash. If the parameters regarding communication
(Ad01) are changed, communication will be re-initialised
from the zone control.
Below we provide the meanings for the operating pa-
rameters:
Ad01 - Network address for the zone control (1÷32)
- Default 2;
Ad02 - Supervisor address - (Do not change)
Br01 - Baud rate - (Do not change)
Br02 - Baud rate supervision - (Do not change)
En01 - Enable buzzer (0÷1) - Default 1.
Pc01 - Room probe calibration - (Do not change)
rEL - Release firmware indication - (Do not change)
Prot - Select protocol - (Do not change)
The addresses to be used are:
21 = Zone 1
22 = Zone 2
23 = Zone 3
24 = Zone AT
When configuration is complete, restart the control
zone by shutting off and turning the electric power
supply back on.
N.B.: The zone control cannot be used to programme
the time periods, which can only be programmed on
system manager, but it will be possible to manage the
request to operate the zone being referred to manually
by setting the desired set.