2.2.4 Operation in winter mode

Pressing button
the "System Manager Kit" enables both domestic hot
water production and room central heating (M01).
The display shows current day and time, any operating
faults, ambient temperature and humidity percentage
in the main area.
N.B.: press arrows
for any other stored areas.
The "System Manager Kit" allows automatic functioning
in central heating mode, in which a time program man-
ages the room temperature during the hours of the day.
The desired room temperature can be adjusted onto
two independent levels: comfort (
(
). The distribution of these levels throughout the
day or week is controlled by the hourly programming
(see Parag. 2.5).
The "System Manager Kit" is factory set as shown in
the table below. If this should not satisfy requirements,
it is possible to modify it as described in the following
chapters.
Days
Mon-Fri
-
Sat-Sun
-
N.B.: the system is designed to function on comfort
and reduced temperature levels depending on the hour
program set. Therefore also during functioning in re-
duced temperature conditions, if the room temperature
measured is below that set, the system can switch-on.

2.2.5 Room antifreeze function

Note: this function is only active in the winter, stand-by
and summer mode.
The antifreeze function has maximum priority with
respect to other settings. When ambient temperature
drops below 5°C a central heating request at minimum
setting is made. This situation remains active until there
is a variation in room temperature of 1°C equal to 6°C
measured in the area where the temperature below 5
°C is detected.
switches to winter operation:
to view the same parameters
) and reduced
16°C
20°C
0 ÷ 24
0 ÷ 24
2.3
DOMESTIC HOT WATER TEMPERATURE
SETTING.
There are two modes for managing domestic hot water:
- Set DHW fixed;
- set DHW automatic.
In the first case it is sufficient to set a SET MANUAL to
have a DHW setpoint that remains unchanged over time.
If wanting to set two different setpoints, for example a
daily one and a night one, it is necessary to enable time
slots and set two different setpoints:
- set COMFORT;
- set ECO.
From the main screen (M01), press arrows
the DHW set is displayed (M02, M03).
M02:
Press the
button again to make the first reading
(DHW band enab.) blink.
Set as desired by pressing arrows
press button
to confirm and for the next value
(Manual Set) to start blinking. Proceed in the same way
to set the next figures.
After setting the last figure, when button is pressed
the cursor no longer blinks and it is possible to change
screens with buttons
At the end press button
main screen.
• Set manual: it lets you set the DHW set-point valid
until the next time range change (M02);
• Temperature.: it displays in real time the domestic hot
water temperature (M02).
• DHW band enab.: enables only the Manual Set to be
configured. If "Yes", Set Comfort and Set Eco can also
be configured (M03).
M03:
Press the
button again to make the first reading
(Comfort Set) blink.
Set as desired by pressing arrows
press button
to confirm and for the next figure
(ECO Set) to start blinking. Proceed in the same way to
set the next figures.
After setting the last figure, when button is pressed
the cursor no longer blinks and it is possible to change
screens with buttons
At the end press button
main screen.
11 11
until
. At the end,
.
twice to go back to the
. At the end,
.
twice to go back to the

Advertisement