Summary of Contents for Immergas System Manager Kit
Page 1
System Manager Instructions and warnings Installer User Electronic control Maintenance technician...
Page 3
Congratulations for having chosen a top-quality Immergas product, able to assure well-being and safety for a long period of time. As an Immergas customer you can also count on Qualified Post-Sales Service, prepared and updated to guarantee constant efficiency of your "System Manager Kit".
5.10 Telephone dialler..........26 Display - firmware revision ........8 5.11 Reset counter............26 5.12 Manual management........... 26 “System manager kit” user settings ....9 5.13 Initialization............27 Start-up..............9 5.14 Cascade parameters..........27 2.1.1 Main page ............... 9 2.1.2 Programming current time and day ....
Page 5
INDEX PAGE System operator - connection to victrix 9.34 System manager - connection to dominus..84 superior 2022............67 9.35 System manager - connection to domotics 9.10 System manager - connection to boiler via with digital signals..........85 modbus rs-485 electronic board.
• The instruction manual must be considered a part of the “System Manager Kit” and must be “kept for future reference”. • The “System Manager Kit” is intended only for the use for which it has been expressly designed. Any other use must be considered improper and therefore dangerous.
DESCRIPTION CONTROL PANEL Key: BUTTONS DESCRIPTION. 1. Button to change the operating mode summer/ The button (Ref. 1 Fig. 1-1) allows you to change the winter/stand-by ( operating mode of the system, specifically: • Summer (only DHW management). 2. Access button to submenus ( •...
Summer - only the dhw heating function is - “Info” menu, to view the “System Manager Kit” input enabled; data (ex. external temperature, flow temperature, set flow temperature, DHW temperature, solar storage Comfort temperature is active;...
“SYSTEM MANAGER KIT” USER 2.1.2 Programming current time and day SETTINGS Press the button to enter the navigation menu. Press buttons until selecting menu “02. PRO- It is possible to set / modify the following parameters: GRAMMING”. - DHW temperature;...
In this status the current day and time are still displayed, along The “System Manager Kit” is factory set as shown in with any operating faults, present humidity percentage the table below. If this should not satisfy requirements, and ambient temperature in the main area.
(see Parag. 2.5). (DHW band enab.) blink. The “System Manager Kit” is factory set as shown in Set as desired by pressing arrows . At the end, the table below. If this should not satisfy requirements,...
• COMFORT SET: it lets you set the DHW set-point in SETTING COMFORT AND REDUCED ROOM TEMPERATURE. the COMFORT time range (refer to settings of DHW time slots) (M03); It is possible to set two different room temperature levels: - setpoint COMFORT; •...
PROGRAMMING OPERATING TIME IN 2.6.2 Weekly hourly program COMFORT MODE. Press the button to enter the navigation menu. In this menu it is possible to: Press buttons until selecting menu “02. PRO- - set 4 calendars for 4 different time slots; GRAMMING”.
2.6.3 Holiday program SYSTEM MANAGEMENT In this menu it is possible to: With this menu it is possible to temporarily disable - activation of SEPARATE HEATING / COOLING system requests with the exception of: MANAGEMENT; - room antifreeze function; - activation of the FANCOIL IN WINTER function. - managing thermal solar system.
2.7.1 Floor Drying function. During active operation, it is possible to check in the INFO pages (I47): A “Floor Drying” function can be enabled to perform - Active Setpoint. Temperature calculated during screed thermal shock on new radiant panel systems, as required heater operation.
Page 16
- Heat pump temporary enable command (D05). The option lets you enable heat pumps according to the time slots that will be set in the next page (D06). Press button for the option “Disable heat pumps” to start blinking. Press arrows to confirm (YES) or cancel (NO) any option.
INFORMATION DHW MENU. - D.H.W. data (I51, I52 and I53) Info In the following pages it is possible to view the main system information, in particular parameters relating to: - zone management; Setpoint 40 °C DHW Temp 45.0 °C - domestic hot water; Request - heat pump management;...
Press arrows to scroll and display all extant alarms. The anomalies displayed in the “System manager kit” are listed in the “Anomalies list” chapter. If no alarm has been triggered, it is still possible to view the “Alarms log” by proceeding as follows:...
Some of these - INTEGRATION: detailed information on integration submenus are protected by a code (which can be used generators. exclusively by the Immergas technician) while others are also visible to the user. - INPUT/OUTPUT: system inputs and outputs. Press the arrows and select “02.
SYSTEM DEFINITION Furthermore, if the setpoint calculated for the dehumid- Within this menu it is possible to set the features of the ification is too high to carry out a request, the alarm is system that need to be managed. signalled and the dehumidifier is stopped.
5.4.2 Heat pumps (P31) - Separate management of central heating and cooling (P65). Allows to control a 3-way valve to choose wheth- The system allows you to choose the model of heat pump er to use the central heating system or the cooling one. used (max.
CENTRAL HEATING (P68) - Enable external temperature probe presence. - Hysteresis ON (P68). The generator turns on for a - Not present setpoint lower than setpoint required + Hysteresis ON. - From heat pump - From boiler - Hysteresis OFF (P68). The generator turns on for a - From the system manager setpoint lower than setpoint required + Hysteresis OFF.
TEMPERATURE REGULATION (T01 ÷ DOMESTIC HOT WATER. T20). This menu will be enabled only if "Yes" has been set under In this menu it will be possible to: “DHW” in the “System definition” menu. - activate operation with external probe; Press the arrows and select “Sanitario”...
SOLAR SYSTEM. N.B.: As soon as the temperature of the manifold falls In this section it will be possible to set the values to below the set setpoint this function is disabled. The manage the solar pump. This menu will be enabled only storage tank's cooling system is also enabled when the if “1”...
INTEGRATION. - Integration limit (X04). If the flow temperature of the In this section it is possible to define auxiliary sources heat pumps is lower than the heating-set value minus to be used to integrate the central heating or integration the activation band divided by 2, then after a period mode of action.
SUPERVISOR. 5.10 TELEPHONE DIALLER. In this section it is possible to set the type of supervision Using digital supervision, illustrated in the previous of the system management kit. paragraph, it is possible to use a telephone dialler to There are two types of supervision: digital and with manage system operational modes.
5.13 INITIALIZATION. - Activation Band to Start or Stop HP (C02). The In this section it is possible to restore the factory settings. cascade generators are activated/deactivated if the By performing this operation all of the operations previ- common delivery probe is outside the set-point range ously carried out will be deleted including time periods, ±...
LIST OF PROGRAMMABLE PARAMETERS. “Main” menu. Range Value Value Description page adjustment default customis. Stand-by, Summer, Working modes Summer with Cooling, Stand-by Winter DHW Time bands enab. No / Yes 10 - 50 (60 with boiler/ DHW Manual set (permanent) electrical res.) DHW Manual set (permanent) 30 - 60...
Page 29
"Set point" menu. Range Value Value Description page adjustment default customis. Party mode No / Yes Winter - Zone 1 Comfort Set 5 - 35 Winter ZN1 Economy Set 5 - 35 Winter - Zone 2 Comfort Set 5 - 35 Winter ZN2 Economy Set 5 - 35 Winter - Zone 3 Comfort Set...
Page 30
“Programming” menu. Range Value Value Description page adjustment default customis. Time 0 - 23 Minutes 0 - 59 Monday / Tuesday / Wednesday / Thursday Day of the week / Friday / Saturday / Sunday Day of year 1 - 31 Month of year 1 - 12 Year...
Page 31
Range Value Value Description page adjustment default customis. CAL1, CAL2, Zone 1: Tuesday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 1: Wednesday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 1: Thursday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 1: Friday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 1: Saturday CAL1 CAL3,CAL4 CAL1, CAL2,...
Page 32
Range Value Value Description page adjustment default customis. CAL1, CAL2, Zone 4: Friday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 4: Saturday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 4: Sunday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 5: Monday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 5: Tuesday CAL1 CAL3,CAL4 CAL1, CAL2,...
Page 33
Range Value Value Description page adjustment default customis. CAL1, CAL2, Zone 7: Sunday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 8: Monday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 8: Tuesday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 8: Wednesday CAL1 CAL3,CAL4 CAL1, CAL2, Zone 8: Thursday CAL1 CAL3,CAL4 CAL1, CAL2,...
Page 34
Range Value Value Description page adjustment default customis. Holiday end day 1 - 31 Holiday end month 1 - 12 Holiday end year 0-99 Enable holiday Yes/No “System Management” menu. Range Value Value Description page adjustment default customis. Set cooling (separate heating / cooling 5-25 management) Enable use of fancoil in WINTER...
Page 35
Range Value Value Description page adjustment default customis. CAL1, CAL2, Heat Pump Power Reduction: Monday CAL1 CAL3,CAL4 CAL1, CAL2, CAL3, Heat Pump Power Reduction: Tuesday CAL1 CAL4 CAL1, CAL2, CAL3, Heat Pump Power Reduction: Wednesday CAL1 CAL4 CAL1, CAL2, CAL3, T Heat Pump Power Reduction: hursday CAL1 CAL4...
Page 36
“Service \ System definition” menu. Range Value Value Description page adjustment default customis. Plant type 1 - 8 Zones number No / Yes DHW Enable No / Yes Mode Hot, Cold, Hot/Cold NO, Rem. Control, Remote panel, Zone Comm. Remote panel Control, Temp-humid probe Thermostat...
Page 37
Range Value Value Description page adjustment default customis. Mode Hot, Cold, Hot/Cold Comm. No, temp-hum. probe Thermostat No / Yes Type Fixed / Mixed Mixed Zone probe No / Yes Humidostat No / Yes Dew Point No / Yes En. Dehum. No / Yes Mode Hot, Cold, Hot/Cold...
Page 38
Range Value Value Description page adjustment default customis. 5 = Room 5 6 = Room 6 Names Zone 5,6,7,8 7 = Room 7 8 = Room 8 Main zone 1 - 4 Dehum. Set Max 15 - 50 Alarm set 15 - 50 Request from fancoil zone OFF/ON...
Page 39
Range Value Value Description page adjustment default customis. Power 50-100 % 75 % Pump Logic Max sp / Modul Modul Minim. Speed 19-50 % 50 % Max. Speed 50-100 % 100 % Delta T 2-20 Circulator anti-block Yes/No Flow switch Reduction enable NO/YES Power...
Page 40
Range Value Value Description page adjustment default customis. Audax 6/ Audax 8 / Audax 12/ Audax 16 /Audax 16 Mono / Audax Top 6 /Audax Top 8/Audax Top 12 / Ind. 14 Audax Top 16 /Audax Top 18 / Audax Top 21 /Audax 6 kW/ Audax 8 –...
Page 41
Range Value Value Description page adjustment default customis. Maintain: NO/YES Pump NO/YES Upon Request / In In tempera- Zone Activation On Request temperature ture Central Heating - Hyst. ON -10 - +20 Central Heating - Hyst. OFF -10 - +20 Central Heating - Offset gen -10 - +30 Puffer Cooling - Hyst.
Page 42
Range Value Value Description page adjustment default customis. Zone 05 - Heating phase Set max 20 – 85* Room probe Yes/No Zone 01 - Heating phase External probe No/Yes Zone 06 - Heating phase Set min 20 – 85* Zone 06 - Heating phase Set max 20 –...
Page 43
Range Value Value Description page adjustment default customis. Zone 01 - Heating phase External probe No/Yes Set min 20 – 85* Set max 20 – 85* External t. limit - Heating phase Min ext. -20 - 0 External t. limit - Heating phase Max ext. 5 - 25 Set Deum.
Page 44
“Assistance \ Solar” menu. n° Range Value Value Description pagina adjustment default customis. Solar pump 1 Δt On 1 - 20 Solar pump 1 Δt Off 0,5 - 19,5 Solar pump 2 Δt On 1 - 20 Solar pump 2 Δt Off 0,5 - 19,5 Tank Max.
Page 45
“Assistance \ Supervisor” menu. Range Value Value Description page adjustment default customis. Digital Mangement Sys Enable No / Yes ---, Carel, Modem RS Protocol supervision system 1 Winload 232, Modbus, Winload 1200, 2400, 4800, Baudrate supervision system 1 19200 9600, 19200 Address supervision system 1 1 - 100 ---, Carel, Modem RS...
Page 46
Range Value Value Description page adjustment default customis. STOP/OPEN/ Expansion 2: Zone pump CLOSE Expansion 2: 3P Valve OFF/ON Expansion 2: Dehumidification OFF/ON Expansion 2: Deh. and Clim. OFF/ON STOP/OPEN/ Expansion 3: Zone pump CLOSE Expansion 3: 3P Valve OFF/ON Expansion 3: Dehumidification OFF/ON Expansion 3: Deh.
Page 47
Range Value Value Description page adjustment default customis. Audax 1: Mode -120 - 120 Audax 1: Set Freq. NO/YES Audax 1: High pressure switch test 0 - 100 Off, Cooling Test, Heating Test, Ramp Audax 2: Circ. Test Speed Cooling Test, Ramp Heating Test Audax 2: Mode -120 - 120...
NOTES FOR DEVICES Procedure to change parameters FOR ZONES In this mode, all symbols are shut off, except for the following fields: NOTES FOR ZONE CONTROL indicates the value of the parameter currently being changed; 88:88 indicates the name of the parameter currently being changed.
NOTES FOR ZONE REMOTE Programming current time and day. Press and hold CONTROL the “time band ” button until the “ ” func- Clock Please refer to the relevant instructions sheet for instal- tion appears. lation instructions. The required addresses to use are: 31 = Zone 1 32 = Zone 2 33 = Zone 3...
Page 50
Time slots adjustment. The “Time band” parameter Ignition. Press and hold the “on / off ” button; the enables to adjust the room temperatures in time slots, remote control goes into stand-by and displays the it is possible to adjust up to a maximum of 6 time slots operating modes, the room temperature and the time.
Page 51
- Select the time slots, which are shown according to the Time slot activation. By pressing the button “ ” one sequence below: can activate system operation according to the settings made previously. The activation of the time slot mode is signalled by the activation of the relative symbol “...
Page 52
Room temperature manual adjustment. In the event the Anomalies display. In the event there is an anomaly in time slots are not used, one can set the room temperature progress, the remote control displays the status via the simply by turning the main selector. symbol “...
12:34 Ma 8 Lug 2014 20.6 °C 13°C Zona 1 Set ambiente 21.0°C Modo Menu Zona Key: 1 - Main parameters switch with button to confirm and save data 2 - Left context button 3 - Right context button 4 - Display 7-12 NOTES FOR THE NOTES FOR DOMINUS (OPTIONAL).
GENERATORS 8.1.2 Magis pro V2 configuration CONFIGURATION Parameter T02 and the parameter families UXX, RXX, IXX are automatically set by the system operator. HEAT PUMPS CONFIGURATION. Required settings on the indoor unit panel: - A12 = OFF; 8.1.1 Communication analysis - A13 = 1;...
8.1.3 Magis Combo V2 configuration 8.1.4 Magis M configuration Parameter T02 and the parameter families UXX, RXX, For correct operation of the System Manager with IXX are automatically set by the system operator. Magis M, it is ALWAYS necessary to install the Magis Required settings on the indoor unit panel: M hybrid system coupling resistor (supplied as stand- - A12 = OFF;...
8.1.5 Audax configuration - Configure (P41). Select “Yes” to start parameterisation. - Orientation. In presence of several heat pumps com- This heat pump family includes the following models: municating with each other, setting the machines with - Audax 6 different addresses is required. - Audax 8 Machine Address...
8.1.6 Work range of heat pumps. - Test cooling - Test central heating The maximum and minimum temperatures of the heat pumps depend on the type of machine installed. - Test cooling with ramp The following tables highlight the operational limits. - Test central heating with ramp - Set Freq.: Magis M...
The connection of boilers to the System Manager can be - Connection via dry contact (boiler ON/OFF). made in 4 different ways, which can be set on page X01 The following table shows in which mode Immergas depending on the model: boilers must be connected and which functions are - Connection via Immergas BMS (BMS boiler);...
8.2.1 Connection via Immergas BMS. 8.2.4 Connection via analogue 0-10 V signal and DHW thermostat. Connection via Immergas BMS takes place on the ter- minals dedicated to BMS communication in supported This mode activates heating requests via the 0-10 V input products.
WIRING DIAGRAMS SYSTEM MANAGER - POWER SUPPLY CONNECTION. PWM 0/10V J8 ISOLATED input voltage: 24Vac (+10%-15%); 50/60Hz 48Vdc (36Vmin...71Vmax) max power:8VA/6W Key: A13 - System manager T1 - Class II transformer of at least 30 VA with 24 Vac output voltage (not supplied with the System manager) 1 - Power supply 230 Vac - 50 Hz 2 - Transformer 230 Vac - 24 Vac...
SYSTEM OPERATOR - CONNECTION TO MAGIS M. J8 ISOLATED GNX + - Modbus connection AWG 20/22 type Collegamento Modbus shielded cable cavo schermato tipo AWG 20/22 Screen Schermo (H2) (H1) (Y) (E) For the correct connection betwe- en control panel and CN30 con- nector, please refer to the heat pump's operating and installation manual...
SYSTEM MANANGER - MAGIS PRO V2 BATTERY CONNECTION J8 ISOLATED J9 input voltage: max power:8VA/6W Key: A13 - System manager 1 - Internal Unit Magis Pro V2 n°1 2 - Set: A21 = 11 3 - Internal Unit Magis Pro V2 n°2 4 - Set: A21 = 12 5 - Internal Unit Magis Pro V2 n°3 6 - Set: A21 = 13...
K25: - Support relay EMR 230/24 Vac 16A (not supplied) 1 - Power supply 230/24 Vac - 50 Hz 2 - Power supply 400+N/230Vac - 50 Hz Note: - The B2 probe is fitted as standard on the Immergas storage tanks. 66 66...
9.13 SYSTEM MANAGER - CONNECTION TO BOILER THROUGH TA INPUT. 9-13 J8 ISOLATED J9 input voltage: Key: max power:8VA/6W A13 - System manager A3 - Boiler P.C.B. (generic) K20 - Relay EMR 12 V DC Note: - The K20 relay contact must be connected to the boiler TA clamps 9.14 SYSTEM MANAGER - CONNECTION TO BOILER ALARM SIGNAL.
3 - B (to system) input voltage: 24Vac (+10%-15%); 50/60Hz Note: - The B2 probe is fitted as standard on 48Vdc (36Vmin...71Vmax) the Immergas storage tanks max power:8VA/6W - Control (J10): Open -> switch to system Closed -> switch to storage tank...
9.19 SYSTEM MANAGER - EXPANSION ZONE PUMP CONNECTION. F - Function I - Expansion Addresses Z1 - Zone 1 Z2 - Zone 2 Z3 - Zone 3 Z4 - Zone 4 Z5 - Zone 5 Z6 - Zone 6 Z7 - Zone 7 Z8 - Zone 8 I1 - Address 1 I2 - Address 2...
9.21 SYSTEM MANAGER - EXPANSION ZONE MIXER CONNECTION. 9-21 Key: F - Function A15 - Zone expansion kit I - Expansion Addresses M31 - Zone mixing valve Z1 - Zone 1 1 - Power supply 230 Vac - 50 Hz Z2 - Zone 2 2 - Open Z3 - Zone 3...
9.22 SYSTEM MANAGER - CONNECTION TO ZONE ROOM THERMOSTATS. 9-22 Key: A15: - zone expansion kit S20 - Zone room thermostat or potential-free contact to request 1 - Power supply 24Vac - 50Hz 2 - Remove any jumper ID1-G to connect TA F - Function I - Expansion Addresses Z1 - Zone 1...
9.23 SYSTEM MANAGER - CONNECTION TO SAFETY THERMOSTAT. 9-23 PWM 0/10V J8 ISOLATED input voltage: 24Vac (+10%-15%); 50/60Hz 48Vdc (36Vmin...71Vmax) max power:8VA/6W Key: A13 - System manager Note: - This connection is necessary in the presence of zone expansions with TA contacts / temperature-humidity probes/zone controls.
9.25 SYSTEM MANAGER - CONNECTION TO ZONE REMOTE PANELS. 9-25 J8 ISOLATED J9 input voltage: A32 - 1,2,3,HT max power:8VA/6W Key: A13 - System manager A32-1,2,3,HT - Zone remote panel 9.26 SYSTEM MANAGER - CONNECTION TO TEMPERATURE AND HUMIDITY PROBE. Key: 9-26 A15: - zone expansion kit...
9.36 SYSTEM MANAGER - CONNECTION TO DOMOTICS WITH COMMUNICATION PROTOCOL. 9-36 PWM 0/10V J8 ISOLATED input voltage: 24Vac (+10%-15%); 50/60Hz Serial Card 1 48Vdc (36Vmin...71Vmax) max power:8VA/6W Key: A3 - System manager Note: - Communication protocols: 1 - Domotics management system Modbus 9.37 SYSTEM MANAGER - CONNECTION TO PHONE DIALLER.
9.41 SYSTEM MANAGER - THREE-WAY CONNECTION INTEGRATION INTO SYSTEMS WITH PUFFER. 9-41 A15-4 Key: - Command (J7) 1 - Power supply 230 Vac - 50 Hz Open -> switch to PdC 2 - A (boiler) Closed -> switch to boiler 3 - B (heat pump) 4 - AB (puffer) - We recommend applying 2 commutation...
9.42 SYSTEM MANAGER - CONNECTION TO INERTIAL STORAGE TANK PROBE. 9-42 J8 ISOLATED J9 input voltage: max power:8VA/6W A15 - 4 Key: A13 - System manager A15-4 - Address 4 zone expansion kit Notes: - Enable the expansion only when using the M10 - Bleeding circulator (optional) M10 circulator.
9.46 SYSTEM MANAGER - CONNECTION TO EXTERNAL PROBE 9-46 J8 ISOLATED J9 Key: input voltage: A13 - System manager - External probe max power:8VA/6W 9.47 SYSTEM MANAGER - CONNECTION TO PLATE EXCHANGER DOWNSTREAM OF HEAT PUMP. 9-47 Key: A15-5 - Zone expansion kit with address 5 K5 - Relay type EMR 12 V dc M11 - Pump downstream of the plate heat exchanger on heat pumps...
LIST OF A0126 Zone 2 room temperature probe anomaly ANOMALIES. A0127 Zone 3 room temperature probe anomaly HT Zone room temperature probe A0128 Alarm malfunction alarm Alarm Description Code A0129 Zone 1 humidity probe anomaly Domestic hot water boiler/inlet probe A0012 A0130 Zone 2 humidity probe anomaly...
Contribution to the environmental heating Class Description seasonal energy efficiency +4 % System manager kit System manager kit combined with 3 devices VIII +5 % (zone remote panel, zone remote control, humidity temperature sensor) 95 95...
Page 96
This instruction booklet is made of ecological paper immergas.com Immergas S.p.A. 42041 Brescello (RE) - Italy Tel. 0522.689011 Fax 0522.680617...