Technical data
7.3 With PROFIBUS PA / with FOUNDATION Fieldbus
 
For connecting to power
source with the following
peak values
Effective internal capaci‐
tance and inductance
 
Digital input DI1
(terminals 9 and 10) electrical‐
ly connected to the bus circuit
 
Galvanic isolation
For basic device without ex‐
plosion protection and for
basic device with Ex "db"
For basic device Ex "ia"
For basic device Ex "ic", "ec",
"tb"
Test voltage
7.3.2

PROFIBUS PA communication

Communication
C2 connections
Device profile
Response time for a master tele‐
gram
Device address
PC parameter assignment soft‐
ware
68
Basic device
Basic device with
without explosion
explosion protec‐
protection
tion Ex "db"
-
Umax ≤ 35 V
Pmax ≤ 2.5 W
-
-
Jumpered or connection to switch contact.
Suitable only for floating contact; max. contact load
 
Galvanic isolation between the basic device and the input for safety shutdown and the
outputs of option modules.
The basic device, the input for safety shutdown, and the outputs of option modules are
individual intrinsically safe circuits.
Galvanic isolation between the basic device and the input for safety shutdown and the
outputs of option modules.
Layers 1 + 2 as per PROFIBUS PA, transmission technique as per IEC 1158-2;
slave function layer 7 (protocol layer) as per PROFIBUS DP,
standard EN 50170 with the extended PROFIBUS functionality
(all data is acyclic, manipulated variable, feedbacks and statuses are additionally cyclic)
Four connections with the master class 2 are supported; automatic connection termination
60 s after interruption in communication
PROFIBUS PA profile B, version 3.0; over 150 objects
Typically, 10 ms
126 (in the as-delivered condition)
SIMATIC PDM; supports all device objects. The software is not included in the scope of
delivery.
Basic device with
explosion protec‐
tion Ex "ia", Ex "db ia"
U
 ≤ 30 V
i
I
 ≤ 100 mA
i
P
 ≤ 1 W
i
Negligible
< 5 μA with 3 V
DC 840 V, 1 s
Compact Operating Instructions, 11/2022, A5E03436620-AG
Basic device with
explosion protec‐
tion Ex "ic", "ec", "tb"
"ic":
U
 ≤ 30 V
i
I
 ≤ 100 mA
i
"ec"/"tb":
U
 ≤ 30 V
n
I
 ≤ 100 mA
n
Negligible
SIPART PS2 (6DR5...)