GENERAL WARNINGS.
All Immergas products are protected with suitable transport
packaging.
The material must be stored in a dry place protected from the
weather.
This instruction manual provides technical information for
installing the Immergas kit. As for the other issues related to kit
installation (e.g. safety in the workplace, environmental protection,
accident prevention), it is necessary to comply with the provisions
specified in the regulations in force and with the principles of good
practice.
Improper installation or assembly of the Immergas appliance and/
or components, accessories, kits and devices can cause unexpected
problems for people, animals and objects. Read the instructions
provided with the product carefully to ensure proper installation.
Installation and maintenance must be performed in compliance
with the regulations in force, according to the manufacturer's
instructions and by professionally qualified staff, meaning staff
with specific technical skills in the plant sector, as envisioned by
the law.
USE.
The proportional dispenser is used to dose in water the Cillit®-55
M-H Universal, a compound of natural mineral salts which
efficiently prevent limescale deposits and corrosions from
forming inside the circuits for the production of domestic hot
and cold water.
The dispenser must not be installed in places where the tem-
perature falls below 0°C.
Protection from deposits inside the systems is required by D.P.R.
59/2009, by the UNI-CTI 8065 standard and so by M.D. 37/08.
The dispenser is in compliance to M. D. 174/04 and to M.D.
25/12, concerning the purity of materials.
Please leave a copy of this instruction manual near the equip-
ment.
DISPENSER MAIN COMPONENTS.
10
3
9
1
2
IE

TECHNICAL DATA.

Max. water temperature ...............................
Max. water temperature ................................
Rated flow rate ...............................................
Pressure drop at the rated flow rate.............
Autonomy .......................................................
Load Cillit®-55 ................................................
Cillit®-55 supply .............................................
CHECKS AND MANAGEMENT
Check the product charge through the transparent cup, when
the cup is empty, top up as described in the paragraph "Loading
the dispenser". For refills use only Cillit®-55 M-H Universal.
In addition to invalidating the guarantee, the use of different
products can cause damage to the dispenser and to the systems.

TROUBLESHOOTING

If the appliance does not consume the product, contact a licen-
sed company (for example the Immergas Technical Assistance
Service) for the required checks, since in this case the dispenser
is not working.
Possibile causa
Shut-off valves closed
Appliance non deaerated
Load not sufficiently
hardened
Inlet and/or outlet nozzles
clogged
ASSEMBLY OF THE DIAPHRAGM UNIT ON THE
POLYPHOSPHATE DISPENSER HEAD
Mount the OR contained in the kit in the relevant seats of the
diaphragm unit (3) (see figure 1).
Using the relevant screws contained in the kit, connect the
diaphragm unit (3) to the head (2) being careful to follow the
direction of the arrow (9) on the diaphragm unit (see figure 1),
then fit the diaphragm unit (3) with the fittings (1-10) contained
in the kit (see figure 1), using a sealant that ensures a perfect seal.
Key:
1 - Brass fitting G3/4" M - G1/2" M
4
2 - Head
3 - Diaphragm unit
4 - Drain screw
5 - Solubilization disc
6 - Bellows
7
7 - Ring nut for basin
8 - Transparent basin
9 - Assembly direction
6
10 - Fitting
8
5
5
30°C
40°C
1,5 m
/h
3
0,29 bar
25 m
(approx.)
3
80 g.
No. 2 bags 80 gr.
Rimedi
Open the valves
Dearate the appliance
Refill following the instructions
Clean the nozzles