Appendix C, Powerbox Mechanical Specifications - SolarEdge SE8k Installation Manual

Three phase inverters
Hide thumbs Also See for SE8k:
Table of Contents

Advertisement

SolarEdge Installation Guide for Three Phase Inverters – EU
PowerBox Mechanical
About This Appendix
This appendix presents the mechanical specifications for the SolarEdge
PowerBoxes.
Use M8 screws and washers to secure the PowerBox units to the racking.
NOTE
:
SolarEdge does not provide the screws, nuts or washers because the required
sizes and lengths vary for different racks.
CAUTION:
Before installing directly on the module or module frame, first consult the module
manufacturer for information about the proper positioning and its impact on the
module warranty.
Mark all mounting hole locations.
Each PowerBox must be attached to the rack using both mounting
holes.
Drill the holes.
CAUTION:
Do not drill through the PowerBox or through the mounting holes. The strong
vibrations created by the drill can damage the PowerBox.
PowerBox Mechanical Specifications
Appendix C
Specifications
72