THOMSON DFT-6500 User Manual

Battery data logger

Advertisement

Quick Links

DFT-6500 Battery Data Logger
Users Manual
THOMSON TECH CO LTD
www.thomsontesting.com

Advertisement

Table of Contents
loading

Summary of Contents for THOMSON DFT-6500

  • Page 1 DFT-6500 Battery Data Logger Users Manual THOMSON TECH CO LTD www.thomsontesting.com...
  • Page 2: Table Of Contents

    DFT-6500 Battery Data Logger Instruction Manual Table of Contents Chapter 1 Overview ............................2 Chapter 2 Functions ............................3 Chapter 3 Features ............................3 Chapter 4 Technical specification ........................4 Chapter 5 Battery Data Logger Sketch diagram ..................4 Chapter 6 Host Wi-Fi connection configuration ................... 5 Chapter 7 Software operation interface diagram ..................
  • Page 3: Chapter 1 Overview

    DFT-6500 Battery Data Logger Instruction Manual Chapter 1 Overview DFT-6500 Battery Data Logger is a Wi-fi monitoring system for the real time monitors of battery performance and state and analyzes the battery performance development trend to judge the battery service life by the battery cell voltage, battery string total voltage, battery string total current and the environment temperature as the main monitoring parameters,.
  • Page 4: Chapter 2 Functions

    DFT-6500 Battery Data Logger Instruction Manual (5) Cell Data Case: Each case can monitor max 12 cells simultaneously. (6) Temperature sensor. Measuring range: -40 ~ 125 ° C. (7) USB to UART (TTL). Host working parameters are configured. (8) There are also Cell-Data-Case voltage test Lines Kit with the same number of Cell-Data-Case.
  • Page 5: Chapter 4 Technical Specification

    DFT-6500 Battery Data Logger Instruction Manual Chapter 4 Technical specification Communication WIFI 2V/6V/12V 0.5%rdg+6dgt Single-cell voltage Accuracy Overall voltage range 12V-380V (Cases depending on the total String voltage) 0-200A Overall current range (other specifications available) Connections Number Max 128 Cell...
  • Page 6: Chapter 6 Host Wi-Fi Connection Configuration

    DFT-6500 Battery Data Logger Instruction Manual Chapter 6 Host Wi-Fi connection configuration The Monitor host Wi-Fi connection needs to be configured by a USB to UART communication line.Connect the communication line to the computer and the monitoring host. Configure the cable UART configuration interface Monitor host Wi-Fi to set the UART operating parameters Example: The PC serial port tool software sends "$WIFI, dczz_Wi-Fi5, dczz13509650307,"...
  • Page 7: Chapter 7 Software Operation Interface Diagram

    DFT-6500 Battery Data Logger Instruction Manual Chapter 7 Software operation interface diagram 7. 1 Software operation There are two ways to run the software: (1) Start → program → Battery Data Management Software, and click to run; (2) Double-click the icon of the "Battery Data Management Software" → desktop and start running.
  • Page 8: Chapter 8 Battery Discharge Monitoring & Data Viewing & Export Reports

    DFT-6500 Battery Data Logger Instruction Manual Chapter 8 Battery discharge monitoring & data viewing & export reports 8.1 Monitoring For the monitoring of battery discharge, the local site must be established before monitoring, and the establishment process is shown in the following figure:...
  • Page 9: Remote Operation

    DFT-6500 Battery Data Logger Instruction Manual 8.2 Remote operation The PC with the host installed by Wi-fi as follows: Wi-fi mode: Click the network icon in the lower right corner, find the SSID with the word network FDY00_xxxxxx, click "Connect" after finding it, and enter the password: FDY12345678...
  • Page 10 DFT-6500 Battery Data Logger Instruction Manual After the connection is successful, as shown in the preceding figure...
  • Page 11 DFT-6500 Battery Data Logger Instruction Manual Click the "Data Logger" icon to enter the main interface. The right column shows the host and Cell-Data-Case to be connected, the icon is "tick" to indicate the connection, you can also select a Case, click "Disconnect", after disconnecting, the icon of the selected case is crossed.
  • Page 12 DFT-6500 Battery Data Logger Instruction Manual Click "Reset", then all connections are cleared, re-search the machine and connect. Click "Experiment" to enter the measurement interface. First set the "test parameters" according to the actual situation, if the network connection is normal, Click "Start Test", then "Inspector"...
  • Page 13 DFT-6500 Battery Data Logger Instruction Manual Real-time data interface (above) Report data interval: During the measurement process, you can also specify the data interval for the report data in order to export the report data. During the test, if you want to stop the test manually, you can click "Stop Test".
  • Page 14: View Reports

    DFT-6500 Battery Data Logger Instruction Manual Each cell graph of min 6-pcs (Above) 8.3 View reports After completing the measurement, switch to "Test Record List", click "Battery string Information List", and below "Test Record List" to select the data you want to view. Select one of the items "Double-click", or click...
  • Page 15: Export Report

    DFT-6500 Battery Data Logger Instruction Manual 8.4 Export report Click the View Report button in the lower right corner to view the data report. As shown in the following figure:...
  • Page 16 DFT-6500 Battery Data Logger Instruction Manual Click "Save Report" to see the data report in excel or RTF format. After the report export is completed, a report will pop up, and in Sheet1 you can see the table header, test units, related parameters, result statistics, and you can also see the histogram of each cell body, and sheet2 is the detailed data of all measurements.

Table of Contents