Immergas Victrix TT Instructions And Warnings

Immergas Victrix TT Instructions And Warnings

Multi-zone kit
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

COD. 3.028444
KIT
Foglio istruzioni
IT
e avvertenze
MULTIZONA
Instructions
IE
MULTI-ZONE
and warnings
KIT
Victrix TT
Victrix Exa
Victrix Tera

Advertisement

Table of Contents
loading

Summary of Contents for Immergas Victrix TT

  • Page 1 COD. 3.028444 Foglio istruzioni e avvertenze MULTIZONA Instructions MULTI-ZONE and warnings Victrix TT Victrix Exa Victrix Tera...
  • Page 2: Avvertenze Generali

    AVVERTENZE GENERALI. DESCRIZIONE DISPOSITIVO. DATI TECNICI. Tutti i prodotti Immergas sono protetti con idoneo Il kit Multizona è una scheda in grado di gestire Alimentazione: ....230 Vac +10 % / -15 % imballaggio da trasporto. impianti di riscaldamento a zone miste (zone alta Temperatura di funzionamento: -10 °C / +60 °C...
  • Page 3 Composizione Kit Rif. Descrizione Quantità 1 - 3 Centralina multizona Vite Vite per tassello AF 3,9 x 25 Tassello 5 x 25 Fermacavi Fusibile rete 3,15 AF ø5 Part. A...
  • Page 4: Allacciamento Elettrico

    La scheda rileva un’anomalia sulla sonda bassa tem- Non vengono soddisfatte le richieste della zona miscelata bassa temperatura peratura (optional). (bassa temperatura) (1) (1) Se il blocco o l’anomalia persiste è necessario chiamare una impresa abilitata (ad esempio il Servizio Assistenza Tecnica Immergas)
  • Page 5 PROGRAMMAZIONE SCHEDA Nel caso di utilizzo di 2 schede multizona in e scorrere le Premere il pulsante ELETTRONICA. cascata, è necessario programmare le singole opzioni presenti fino a che comprare la scritta Tutte le funzioni sono impostabili unicamente schede PRIMA di effettuare tutti i collegamenti, “CODICE”...
  • Page 6 Al termine della funzione la miscelatrice viene La scheda è dotata di una funzione che fa partire Immergas. Il collegamento elettrico della sonda chiusa. la pompa almeno 1 volta ogni 24 ore per la durata...
  • Page 7: Schemi Elettrici

    SCHEMI ELETTRICI. Schema elettrico kit multizone, configurazione 4 zone alta temperatura. Legenda: - Comando amico remoto zona 1 ÷ 4 M10 - Circolatore zona 1 ÷ 4 M32 - Valvola di zona 1 ÷ 4 S20 - Termostato ambiente zona 2 ÷ 4 SW1 - Selettore impostazione scheda Schema elettrico kit multizone, configurazione 1 zona alta temperatura - 1 zona bassa temperatura.
  • Page 8 Schema elettrico 2 kit multizone, configura- zione 7 zone alta temperatura.
  • Page 9 Schema elettrico 2 kit multizone, configurazione 2 zone bassa temperatura - 1 zona alta temperatura.
  • Page 10: Schemi Idraulici

    SCHEMI IDRAULICI. Schema idraulico kit multizone, configurazio- ne 4 zone alta temperatura.
  • Page 11 Schema idraulico kit multizone, configura- zione 1 zona alta temperatura - 1 zona bassa temperatura. Legenda: B3 - Sonda mandata zona 1 bassa temperatura -1 - Comando amico remoto zona 1 bassa temperatura -2 - Comando amico remoto zona 2 alta temperatura E7-1 - Termostato sicurezza zona 1 bassa temperatura M10-1 - Circolatore zona 1 bassa temperatura M10-2 - Circolatore zona 2 alta temperatura...
  • Page 12: General Warnings

    Dimensions (L x H x D): ..110 x 175 x 50 mm - 1 high temperature zone and 1 low temperature mation for installing the Immergas kit. As for the Electrical system protection: ....... IP20 zone controlled individually by a dedicated other issues related to kit installation (e.g.
  • Page 13 Kit composition Quan- Ref. Description tity 1 - 3 Multi-zone control unit Screw Screws for plug AF 3.9 x 25 Plug 5 x 25 Cable tie Mains fuse 3.15 AF ø5 Part. A...
  • Page 14: Electrical Connection

    The board detects a fault on the low temperature The requests of the mixed zone (low temperature) are probe anomaly probe (optional). not met (1) (1) If the block or anomaly persists, contact an authorised company (e.g. Immergas Technical After-Sales Service).
  • Page 15: Programming The P.c.b

    PROGRAMMING THE P.C.B. In the case of using 2 multi-zone cascade boards, button and scroll the options Press the All functions can only be set from the remote you have to program the individual board BE- present until “CODE” appears, press the “master”...
  • Page 16 PUMP ANTI-BLOCK FUNCTION. combination with Immergas timer thermostats. valve is kept open. The board has a function that starts the pump at The external probe must be connected electrically...
  • Page 17: Wiring Diagrams

    WIRING DIAGRAMS. Multi-zone kit wiring diagram, configuration of 4 high temperature zones. BOARD SETTING Not Used In MASTER (OT-S1) position only connect CARV2 Earth IMG-BUS boiler Boiler low voltage Neutral connection terminals Line Key: 230Vac 50Hz - Comando amico remoto remote control power supply zone 1 ÷...
  • Page 18 Wiring diagram of 2 multi-zone kits, configu- ration of 7 high temperature zones.
  • Page 19 Wiring diagram of 2 multi-zone kits, configuration of 2 low temperature zones - 1 high temperature zone.
  • Page 20: Plumbing Diagrams

    PLUMBING DIAGRAMS. Multi-zone kit hydraulic diagram, configura- tion of 4 high temperature zones.
  • Page 21: External Probe

    Multi-zone kit hydraulic diagram, config- uration of 1 high temperature zone - 1 low temperature zone. EXTERNAL PROBE (OPTIONAL) BOILER Key: B3 - Low temperature zone 1 flow probe -1 - Comando amico remoto remote control low temperature zone 1 -2 - Comando amico remoto remote control high temperature zone 2 E7-1 - Low temperature zone 1 safety thermostat...
  • Page 24 NOTE: correct periodic maintenance is highly recommended. Seguici su Immergas Italia Follow us on Immergas Italia Immergas TOOLBOX L’App studiata da Immergas per i professionisti The App designed by Immergas for professionals Disponibile su Disponibile su Disponibile su immergas.com...