electrical connection
- Open the connection compartment of the control panel.
- Remove the resistance from terminals 36 and 37.
- Connect the boiler probe to the previously freed terminals 36 and
37 (see electrical diagram).
- Connect the wiring of the 3-way motor to the electronic board
of the boiler (connector X1) (see electrical diagram).
- Clamp the connection cables to the boiler wiring.
- Close the connection compartment.
Commissioning.
- Restore pressure to the heating system (see instruction booklet)
and open the domestic hot water circuit. Make sure that first you
have closed the draining valve which was previously opened.
- Put the casing back in place.
- Restore the electrical power supply to the boiler to place it back
in normal operating conditions.
n.b.: the use of the boiler with the production of domestic hot
water is described in the instruction booklet of the boiler in the
user's chapter.
Wiring diagram legend:
1 - Storage tank unit
2 - Boiler probe
3 - Connector to be connected to three-way motor
4 - Terminal block located inside control panel connection compartment
5 - Integrated board
6 - Brown
7 - Blue
8 - White
9 - Black
10 - Red
Connection wiring diagram