Immergas MAGIS M4-30 Instructions Manual page 50

Block heat pumps control panel
Hide thumbs Also See for MAGIS M4-30:
Table of Contents

Advertisement

Automatic setting curve.
e automatic setting curve is the ninth; it is calculated as follows:
State: in the setting of the control panel, if T4H2<T4H1, exchange their value; if T1SETH1<T1SETH2, exchange their value
Table 3
e room temperature curve of the low temperature setting for cooling.
T4
-10 ≤ T4 ≤ 15
1-T1S
2-T1S
3-T1S
4-T1S
5-T1S
6-T1S
7-T1S
8-T1S
Table 4
e room temperature curve of the high temperature setting for cooling.
T4
-10 ≤ T4 ≤ 15
1-T1S
2-T1S
3-T1S
4-T1S
5-T1S
6-T1S
7-T1S
8-T1S
Automatic setting curve.
e automatic setting curve is the ninth; it is calculated as follows:
State: in the setting of the control panel, if T4C2<T4C1, exchange their value; if T1SETC1<T1SETC2, exchange their value
T1S (T1S2)
T1SETH 1
T1SETH 2
T4H 1
15 ≤ T4 ≤ 22
16
17
18
19
20
21
22
23
15 ≤ T4 ≤ 22
20
21
22
23
24
24
25
25
T1S (T1S2)
T1SETC 1
T1SETC 2
T4C1
T4
T4H 2
22 ≤ T4 ≤ 30
11
12
13
14
15
16
17
18
22 ≤ T4 ≤ 30
18
19
20
21
21
22
22
23
T4
T4C2
50
30 ≤ T4
8
9
10
11
12
13
14
15
30 ≤ T4
17
18
19
19
20
20
21
21
5
6
7
8
9
10
11
12
16
17
17
18
18
19
29
20