2.4 COMPONENTS.
Open the front panel to see the temporary button for the
display panel (14 Fig. 4).
This function is used to temporarily start the unit if the remo-
te control is not positioned correctly or if the batteries are flat.
Two modes can be selected with the "TEMPORARY" button:
"AUTO" and "FORCED COOL". When the button is pressed,
the fan coil will run in the following order: AUTO, FORCED
COOL, OFF and then AUTO again.
• AUTO
The OPERATION LED is on and the fan coil runs in
AUTO mode. The remote control works based according
to the signal received.
NOTE
The device is equipped with
a 3-way valve.
It is recommended to set
the balancing valves on the
hydraulic circuit
Key:
1 - Air inlet
2 - Front panel
3 - Display
4 - Air outlet
5 - Horizontal fins
7
8
9
6
6 - Remote control
7 - Water inlet pipe
8 - Water return pipe
9 - Drain pipe
10 - Operation LED
• FORCED COOL
The OPERATION LED flashes, the fan coil switches to
AUTO mode after forced cooling with a HIGH fan speed
for 30 minutes. The remote control is not active.
• OFF
The OPERATION LED turns off. The fan coil is OFF, while
the remote control is reactivated.
Note: for the remote control instructions, see chapter 4.1
"Remote controller".