Download Print this page

Kit Installation - Immergas 3.019229 Manual

Safety marker thermostat kit

Advertisement

Available languages

Available languages

MODELS:
VICTRIX SUPERIOR
VICTRIX ZEUS SUPERIOR
VICTRIX TT
VICTRIX ZEUS
VICTRIX EXA
VICTRIX TERA - VICTRIX TERA V2
VICTRIX TERA VIP
VICTRIX OMNIA
VICTRIX PRO 35/55
MAGIS COMBO - MAGIS COMBO PLUS
MYTHOS HP
MAGIS HERCULES PRO
GENERAL WARNINGS
All Immergas products are protected with suitable transport pack-
aging.
The material must be stored in a dry place protected from the
weather.
This instruction manual provides technical information for installing
the Immergas kit. As for the other issues related to kit installation
(e.g. safety at the workplace, environmental protection, accident
prevention), it is necessary to comply with the provisions specified
in the regulations in force and with the principles of good practice.
Improper installation or assembly of the Immergas appliance and/
or components, accessories, kits and devices can cause unexpected
problems for people, animals and objects. Read the instructions
provided with the product carefully to ensure proper installation.
Installation and maintenance must be performed in compliance
with the regulations in force, according to the manufacturer's
instructions and by professionally qualified staff, meaning staff
with specific technical skills in the plant sector, as envisioned by
the law.
Cod. 1.033477 - Rev. ST.000880/007
IE
SAFETY MARKER THERMOSTAT KIT
COD. 3.019229
1
TECHNICAL FEATURES.
Limiter temperature pre-adjustment
Limiter temperature range
Tolerance
Reset
Reset temperature
Degree of protection
Insulation class
Temperature gradient
Head maximum temperature
Bulb maximum temperature
Storage temperature
Capacity on contacts
Outlet
Type of action
Installation situation
Fairlead
Type of assembly

KIT INSTALLATION

- cut power to the appliance by disconnecting the switch upstream
from the boiler;
- fix the thermostat to the system flow pipe using the spring
provided (Fig. 2).
Spring
55 °C
40 - 70 °C
0-10 K
Manual
intervention 25 ± 8K
IP 40
I
< 1 K/min.
55 °C
125 °C
15 - 60 °C
C-1; 0.5 A/250 V~
C-2; 10(2.5) A/250 V~
Contacts in shut-off
1B
Normal room
3/8" GAS
on pipe
2

Advertisement

loading