Installation and maintenance must be performed in compliance
with the regulations in force, according to the manufacturer's
instructions and by professionally qualified staff, intending staff
with specific technical skills in the plant sector, as envisioned
by the Law.
KIT INSTALLATION.
- Remove voltage from the appliance by disconnecting the switch
upstream from the boiler.
- Remove the casing of the appliance and tilt the control panel
as shown in its instruction manual.
- Open the control panel (1) by unscrewing the screws (3) that
3
2
6
5
7
1
Fig. 5-1
ELECTRIC CONNECTION.
The board is composed of three relays (relay 1 = K1; relay 2 =
K2 and relay 3 = K3). The relays can be configured.
N.B.: for the configuration of the functioning options, refer to the
P.C.B. programming paragraph in the appliance instruction book.
4
8
hold the cover (2), paying attention to the rope (4) that supports
the weight of the control panel (1). Once you have removed
the cover, support the control panel (1).
- Assemble the relay board (5), positioning it on the pins (7) and
fasten it with the two cross-head screws (6) (see Figure 5-1).
- Perform the electrical connections between the relay board
(5) and the electronic adjustment card (8) using the two wires
present inside the unit. Connect the external components ac-
cording to requirements following the wiring diagrams given
on the next pages.
- Close the control panel (1), re-mount the casing and re-apply
the voltage to the appliance to take it back to normal function-
ing conditions.
3
Relay board technical data.
Power supply voltage: ............................................. 230VAC 50Hz
contact K1 max capacity: ..........................230VAC 1.00A cosφ 1
contact K2 max capacity: ..........................230VAC 0.75A cosφ 1
contact K3 max capacity: ..........................230VAC 0.75A cosφ 1
Relay K2 enabling contact (X25) SELV 24VDC 10mA (low
voltage in safe conditions)
Attention: do not exceed the maximum load allowed by the fuses
on the mother board (it is added to the boiler load) (3.15A fuse).