WIRING DIAGRAM WITH SEVERAL ZONES.
Using the K1 relay as the ''Main zone control'' and contacts 40
and 41 on the boiler for additional room thermostats, it is pos-
sible to connect several zones according to requirements. The
Comando Amico Remoto remote control always controls the
V2
main zone (zone 1), whereas the relative zone valve is always
and only managed by the K1 relay.
Brown
Brown
Blue
Blue
Brown
Brown
Blue
Blue
Fig. 3-3
WIRING DIAGRAM WITH HEATING PHASE ACTIVE.
The boiler is set up for the management of any external pump,
the pump is powered in concomitance with the heating request
phase.
All the relays can be configured as an active central heating
phase. The diagram represents the connection on relay 2. In the
event this relay is used, it is necessary to jump pins 57 and 58 of
Brown
Brown
Blue
Blue
Fig. 3-4
INTEGRATED P.C.B.
INTEGRATED P.C.B.
RELAY BOARD
RELAY BOARD
Brown
Brown
Blue
Blue
INTEGRATED P.C.B.
INTEGRATED P.C.B.
The
Comando Amico Remoto remote control must be set
V2
with On/Off operation, while the room thermostats require
zone valves with end run contact. The contact must be closed
with valve open hydraulically.
Models with Aquaceleris: remove the P.C.B. to a relay discon-
necting connector X5 from the integrated P.C.B. Then, set relay
3 as "Aquaceleris PTC Supply Voltage" and connect resistance
"E11" as indicated.
connector X25 positioned on the relay board.
In addition, the possible connection to relay 1 and relay 3 is
represented.
Models with Aquaceleris: remove the P.C.B. to a relay discon-
necting connector X5 from the integrated P.C.B. Then, set relay
3 as "Aquaceleris PTC Supply Voltage" and connect resistance
"E11" as indicated.