Download Print this page

Immergas 3.015350 User Manual page 37

Relay interface kit for boiler series magis combo v2, magis combo plus v2, magis pro v2, magis hercules erp, hercules solar 200 condensing erp, hercules condensing erp, hercules mini condensing 32 erp, ares condensing32 erp, victrix superior, victrix supe
Hide thumbs Also See for 3.015350:

Advertisement

Available languages

Available languages

2
INSTRUCTIONS FOR MODELS:
ARES CONDENSING 32 ERP
HERCULES CONDENSING ERP (*) - HERCULES MINI CONDENSING ERP
MAGIS HERCULES ERP
HERCULES SOLAR 200 CONDENSING ERP
(*) N.B.: Hercules Condensing 32 ABT excluded.
Installation and maintenance must be performed in compliance
with the regulations in force, according to the manufacturer's
instructions and by professionally qualified staff, intending staff
with specific technical skills in the plant sector, as envisioned
by the Law.
KIT INSTALLATION.
- Remove voltage from the appliance by disconnecting the switch
upstream from the boiler.
- Disassemble the boiler casing (see instruction book relative to
the boiler model).
- Open the compartment on the control panel for installation of
Ares Condensing 32 ErP - Hercules Mini Condensing 32 ErP
2
2
4
4
3
2
Hercules Condensing ErP
Magis Hercules ErP - Hercules Solar 200 Condensing ErP
3
2
1
the relay board (1) (see figure 2-1 on the basis of your boiler
model).
- Mount the board making the male pin (2) match the hole in the
board (1) and fix it using the cross-head screw (3) (see figure
2-1 on the basis of your boiler model).
- Make the electric connections between the relay board (1) and
the boiler P.C.B. (4) using the relative wiring composed of two
cables supplied with the kit. Connect the external components
according to requirements following the wiring diagrams given
on the next pages.
- Close the control panel, re-mount the casing and re-apply the
voltage to the appliance to take it back to normal functioning
conditions.
1