Relay interface kit for boiler series magis combo v2, magis combo plus v2, magis pro v2, magis hercules erp, hercules solar 200 condensing erp, hercules condensing erp, hercules mini condensing 32 erp, ares condensing32 erp, victrix superior, victrix supe
Hide thumbs Also See for 3.015350:

Advertisement

Available languages

Available languages

WIRING DIAGRAM WITH HEATING PHASE ACTIVE.
The boiler is set up for the management of any external pump,
the pump is powered in concomitance with the heating request
phase.
All the relays can be configured as an active central heating
RELAY BOARD
RELAY BOARD
230V Connection terminal board
230V Connection terminal board
230 Vac 50
230 Vac 50
Hz power
Hz power
supply
supply
Fig. 1-5
WIRING DIAGRAM WITH GENERIC ALARM AND
EXTERNAL GAS VALVE.
The boiler is set up for the management of any generic alarms.
In addition, it is possible to connect an external gas valve to be
connected to an LPG tank. All relays can be configured as a
generic alarm and as an external gas valve.
The diagram shows relay 2 as a generic alarm. In this case, it is
necessary to jump pins 57 and 58 of connector X25 positioned
RELAY BOARD
RELAY BOARD
230V Connection terminal board
230V Connection terminal board
230 Vac 50
230 Vac 50
Hz power
Hz power
supply
supply
Fig. 1-6
phase. The diagram represents the connection on relay 2. In the
event this relay is used, it is necessary to jump pins 57 and 58 of
connector X25 positioned on the relay board.
In addition, the possible connection to relay 1 and relay 3 is
represented.
INTEGRATED P.C.B.
INTEGRATED P.C.B.
Very low
Very low
safety
safety
voltage
voltage
RELAYS K1, K2
RELAYS K1, K2
and K3 CAN BE
and K3 CAN BE
CONFIGURED
CONFIGURED
Low voltage connection terminal board
Low voltage connection terminal board
on the relay board. While relay 3 is configured as an external
gas valve supply.
The ''generic alarm'' signal is enabled whenever one of the en-
visioned anomalies occurs in the boiler (see boiler book under
''Troubleshooting''). The ''external gas valve supply'' control is
enabled together with a burner ignition request in the boiler.
INTEGRATED P.C.B.
INTEGRATED P.C.B.
Very low
Very low
safety
safety
voltage
voltage
Low voltage connection terminal board
Low voltage connection terminal board
35
ELECTRICAL CONNECTIONS
ELECTRICAL CONNECTIONS
OF THE ACTIVE CENTRAL
OF THE ACTIVE CENTRAL
HEATING MODE
HEATING MODE
VIA RELAY K1 AND K3
VIA RELAY K1 AND K3
GENERIC ALARM
GENERIC ALARM
SIGNALLER
SIGNALLER