1 - Floor profile left
2 - Sub-construction
3.2

Safety features and controls

3.2.1

Control elements

Standard control elements
BDE-D
3.2.2

Opening and security sensors (combined)

Each passage area is monitored with opening and security sensors. If an opening or security sensor
is activated during the closing process while in AUTOMATIC or ONEWAY TRAFFIC operating mode,
then the respective sliding door will re-open/reverse again.
NOTICE
The opening sensors located in the direction of the escape route ( (generally inside) must be
set to cover the entire passage width to the depth at a depth of 1500mm and be self-monitor-
ing.
3.2.3

Collision detection

If a door wing hits an obstacle during the closing process, then the door will stop immediately and re-
open.
Equally, the door wing will stop immediately if the door hits an obstacle during the opening process.
The opening process will start anew after 3 seconds at extra slow speed.
3.2.4

Security sensors in the passage area

Each passage area is monitored with its own security sensor. I a security sensor is activated during
the closing process in the AUTOMATIC or ONEWAY TRAFFIC operating mode, then the respective
sliding door will re-open/reverse.
BAL_PROTECT_RC2_RC3_EN_1V0_BLA_121-006454704
Floor rail
3 - Floor profile right
BDE-M
Description
Optional Control elements
Key-operated switch
3