Teledyne Lecroy PCI Express 5.0 U.2 User Manual And Quick Start Manual

Hide thumbs Also See for PCI Express 5.0 U.2:

Advertisement

Quick Links

1
Introduction
Teledyne LeCroy's PCI Express 5.0 U.2/U.3 12 inch Interposer provides a quick and simple means for protocol analysis
of Solid State Drives (SSDs) based on PCI Express (PCIe
Protocol Analyzer, enables PCIe bus traffic between a host backplane and SSD device to be monitored, captured, and
recorded for protocol analysis. The card is compatible with the Summit T516 and Summit T54 and supports data rates
of 2.5 GT/s, 5.0 GT/s, 8.0 GT/s, 16.0 GT/s and 32 GT/s. The interposer supports side band signals such as PERST#,
WAKE#, CLKREQ# and SMBus (SMBCLK, SMBDAT). The interposer can be used with Single x4 Port or Dual x2 Ports.
It also supports U.2 and U.3 standards. It can be used also with Summit T4 and Summit M5x analyzers using a
conversion cable.
When the U.2/U.3 12 inch Interposer is upgraded with CrossSync PHY technology it will provide enhanced power
management and link training equalization debugging capability, enabling users to see and correlate both the physical
and protocol layers in a unified time aligned view. No other solution gives this type of insight into link behavior.
2
Components
The interposer package includes the following components:
PCI Express 5.0 U.2/U.3 12 inch Interposer
3.5 Inch conversion bracket and screws
Two 90 degree conversion brackets and screws
Support bracket for 7mm DUT and screws
DC Power Adapter (+12V @ 5A)
User Manual and Quick Start Guide (this document)
Inspect the received shipping container for any damage. Unpack the container and account for each of the system
components listed on the accompanying packing list. Visually inspect each component for absence of damage. In the
event of damage, notify the shipper and Teledyne LeCroy. Retain all shipping materials for shipper's inspection.
PCI Express
Interposer CrossSync PHY Capable
User Manual and Quick Start Guide
Use this document for quick installation and setup.
®
) protocols. The U.2/U.3 Interposer, used with a Summit
PCI Express 5.0 U.2/U.3 12 Inch Interposer
®
5.0 U.2/U.3 12 Inch

Advertisement

Table of Contents
loading

Summary of Contents for Teledyne Lecroy PCI Express 5.0 U.2

  • Page 1 User Manual and Quick Start Guide Use this document for quick installation and setup. Introduction Teledyne LeCroy’s PCI Express 5.0 U.2/U.3 12 inch Interposer provides a quick and simple means for protocol analysis ® of Solid State Drives (SSDs) based on PCI Express (PCIe ) protocols.
  • Page 2: Switch Configurations

    Switch Configurations The source for the reference clock used by the analyzer to record PCI Express traffic is configurable according to below table. DIP switches and tables for clock selection are located on the rear side of the interposer. SW1:This switch connects the DUT power Indication LED to the bus power. SW1: DUT Power Status LEDs LED Connected (Default) LED Disconnected...
  • Page 3 Screw the drive to the bay to secure it. 4. Install the Interposer into the host system connector. 5. Connect the Summit T516 Analyzer (or other compatible Teledyne LeCroy analyzer) to the interposer using the appropriate analyzer cable (PE028UCA-X Y-cable or PE027UCA-X straight cable). ...
  • Page 4 Connecting the PCI Express 5.0 U.2/U.3 12 Inch Interposer to one Summit T516 Analyzer U.2/U.3 Host Slot Attach support bracket for 3.5 Inch conversion (optional) and drive carrier Summit T516 Analyzer (required). See sections 7 and 8 below. 12V DC from...
  • Page 5 Sideband Header Pinout Table 1: J28 Sideband Header Header Pin Number Sideband Signal Name J28-1 WAKE# J28-2 IFDET#2 J28-3 CLKREQ# J28-4 HPT0 J28-5 IFDET# J28-6 HPT1 J28-7 PRSNT# J28-8 SMCLK J28-9 ACTIVITY# J28-10 SMDAT J28-11 PCIEB_RST# J28-12 DUALPORTEN# J28-13 PCIEA_RST# J28-14 DEV_RESET J28-15...
  • Page 6: Drive Carrier

    INTERPOSER. Teledyne LeCroy's PCI Express 5.0 U.2/U.3 Interposer can be attached to a donor drive carrier. If you plan to insert the interposer into a Chassis backplane you MUST fit the rails from a donor carrier to the interposer before use, to avoid serious damage to the interposer.
  • Page 7 Step 1. Remove the Drive Carrier from the Server Backplane To remove the drive carrier from the server backplane, squeeze the two levers together on the front of the carrier and while gripping the handle provided on the front of the carrier slowly pull the drive carrier out of the server backplane. Set the drive carrier on a suitable work surface (workbench with ESD pad or similar surface).
  • Page 8 Step 4. Remove the Corner of the Side Rail After Removal from Drive Carrier Using a suitable cutting tool (diagonal cutting pliers, etc) remove the corners of the side rails. Typical set of Cut along the corner diagonal of the side rail cutting pliers (or similar tool) Step 5.
  • Page 9 Step 6. Bend Drive Carrier Ears Out of the Way The drive carrier is usually a simple folded piece of fairly thin metal, which can be gently bent flat by hand. If there are metal ears, which held the screws to the ejection catch assembly, they should be gently (by hand) unfolded first before the end of the drive carrier metal is unfolded.
  • Page 10 Step 9. Attach the PCI Express 5.0 U.2/U.3 12 Inch Interposer to the Drive Carrier Slide the Interposer into the drive carrier, using the original mounting screws to hold it in place. The Interposer should be aligned with the same holes the drive carrier would have used. Note: Screw type for use with Drive Carrier: Metric screw, size M3, maximum length: 8mm.
  • Page 11 Support Bracket for 3.5 Inch Conversion To support and stabilize the PCI Express 5.0 U.2/U.3 Interposer within a 3.5" drive carrier, Teledyne LeCroy supplies a bracket kit. The bracket can be mounted on either the top or bottom of the Interposer, depending on the drive carrier configuration.
  • Page 12 Gen5 U.2 Interposer Support bracket Bracket extension installed on the left side of the interposer Gen5 U.2 Interposer Support bracket Bracket extension installed on the right side of the interposer...
  • Page 13 Support Bracket for 7mm DUT To support and stabilize the PCI Express 5.0 U.2/U.3 Interposer within a 3.5" drive carrier, Teledyne LeCroy supplies a bracket kit. The bracket can be mounted on either the top or bottom of the Interposer, depending on the drive carrier configuration.
  • Page 14 Support bracket installation complete...
  • Page 15 CrossSync Capability The PE221UIA-X PCI Express 5.0 U.2/U.3 12 inch Interposer includes CrossSync PHY capability, enabling: • Easy signal access to sideband signals, power rail and refclk probing points • Optional PE130ACA-X upgrade adds preinstalled connections on data lanes for Teledyne LeCroy DH Series high-bandwidth differential oscilloscope probes •...
  • Page 16 Upstream high-speed signal probing points (Optional with PE130ACA-X upgrade) Oscilloscope probing points on CrossSync PHY enabled interposer - rear view...
  • Page 17 High-speed signal probing points are designed exclusively for Teledyne LeCroy DH series high-bandwidth differential probes. A special probe lead, the DH-CSPHY-PCIE5-U2-U3, is used to create the connection between amplifier and interposer.
  • Page 18 Connect DH-CSPHY-PCIE5-U2-U3 lead to desired lane on interposer A polarity indication is printed directly on the interposer next to the probing points (see figure below)- this indicates the side of the connector that should align with the side of the DH-CSPHY-PCIE5-U2-U3 denoted by a white indicator. Note that since devices in a PCIe link may invert polarity of any given lane, this indication on the interposer and probe is provided for consistency, and not as an absolute indication of signal polarity.
  • Page 19 Recommended Oscilloscope Options Oscilloscope Probes Product Description Product Code High-speed Data Signals 8 GHz differential probe with ProLink interface DH08-PL 13 GHz differential probe with ProLink interface DH13-PL 16 GHz differential probe with ProLink interface DH16-PL 20 GHz differential probe with ProLink interface DH20-PL 25 GHz differential probe with 2.92 mm interface DH25-2.92MM...
  • Page 20: Product Description

    Recommended Oscilloscopes CrossSync PHY is compatible with all LabMaster 10 Zi and WaveMaster 8 Zi series oscilloscopes. Below are some recommendations for example test configurations. PCI Express 3.0 - CrossSync PHY and Compliance Test Capable Product Description Product Code 13 GHz (or higher), 40 GS/s, 4ch, 64 Mpts/Ch Serial Data Analyzer with 6.5 SDA 813Zi-B Gb/s Serial Trigger, 8b/10b and 64b/66b decode.
  • Page 21 Dimensions • 12” version: 602.74 mm x 198.37 mm (23.73” x 7.81”)
  • Page 22: Environmental Conditions

    Environmental Conditions • Temperature: Operating 0° to 40°C (32° to 104°F) • Temperature: Non-Operating -10° to 80°C (-14° to 176° F) • Humidity: 0% to 90% RH (non-condensing)
  • Page 24: Trademarks And Service Marks

    Product specifications are subject to change without notice. Summit T516, Summit T54, Summit T416, Summit T48 are Teledyne LeCroy reserves the right to revise the information in this trademarks of Teledyne LeCroy. All other trademarks are property document without notice or penalty.

This manual is also suitable for:

Pci express u.3 12