START UP AND CONFIGURATION.

The unit must be configured by the installer to be adapted to the installation environment (outside weather, installed op-
tions, etc.) and to the competence of the user.
CAUTION
It is important that all of the information in this chapter be read in sequence by the installer and that the system be
configured as applicable.
10.1

OVERVIEW OF DIP SWITCH SETTINGS.

10.1.1
Setting of the function.
The DIP switches S1, S2 and S4 are located on the board of the main hydraulic control module (Chap. 9.3.1 Main control
panel of hydraulic module).
WARNING
Switch off power before making any changes to the DIP switch settings.
DIP Switch
1/2
Reserved
0/0= Without IBH
S1
1/0= With IBH
3/4
0/1= Reserved
1/1= Reserved
DIP Switch
The start-up of the pump O after 24
1
hours will not be valid
2
without TBH
S2
0/0= variable speed pump, maximum head: 8.5 m
0/1= constant speed pump
3/4
1/0= variable speed pump, maximum head: 10.5 m
1/1= variable speed pump, maximum head: 9 m
DIP Switch
Master Unit: Resets the addresses of all
1
the slave units
Slave Unit: Resets its own address
S4
2
IBH for DHW=valid
3/4
Reserved
10.2

INITIAL START-UP AT LOW OUTDOOR TEMPERATURES.

During the initial start-up and when the water temperature is low, it is important to heat the water gradually. Otherwise
the concrete floor could crack due to rapid temperature excursions. For further details, please contact the person in charge
of making the concrete floor.
To perform this operation, the minimum set flow temperature of the water can be reduced to a value between 25°C and
35°C by adjusting it on "FOR SERVICEMAN" (for the maintenance technician).
Chap. 10.5.12 "SPECIAL FUNCTION".
ON=1
ON=1
The start-up of the pump O after 24
hours will be valid
with TBH
ON=1
Maintains the current address
IBH for DHW=not valid
98
OFF=0
OFF=0
ON / ON (4-16 kW)
OFF / ON (18-30 kW)
OFF=0
Default values
-
OFF / OFF
Default values
OFF
OFF
Default values
OFF
OFF
-