Immergas MAGIS M4-30 Use And Installation page 79

Block heat pumps
Hide thumbs Also See for MAGIS M4-30:
Table of Contents

Advertisement

Element
1
Signal cable of the solar energy kit
2
Control panel cable
3
Room thermostat cable
5
Probe cable for Tw2
9
Domestic hot water pump control cable
10/11/23
3-way valve control cable
12
Probe cable for T5
13
Booster heater control cable
15
Unit power cable
(a): Minimum cable cross-section AWG18 (0.75 mm
(b): The thermistor and the connection cable (10 m) are delivered with the domestic hot water tank (T5) or with the zone
2 outlet temperature probe (Tw2).
(c): Chap. 9.7.4 Specifications of standard wiring components.
NOTE
Please use H07RN-F for the power cable. All the cables are connected in high-voltage except for the thermistor cable
and the user interface cable.
• The instruments must be earthed.
• All external high-voltage loads, if in metal or with earthing connection, must be earthed.
• All external load currents must be lower than 0.2A, if the single load current is higher than 0.2A, the load must be con-
trolled by an AC contactor.
• The ports of the wiring terminals R1, R2, and DFT1, DFT2 only supply a signal switch. Please refer to Chap. 9.7.6 To
obtain the position of the ports in the unit.
Description
2
)
1
2
3
Code
1
Hole for high-voltage wire
2
Hole for low-voltage wire
3
Hole for high-voltage or low-voltage cable
4
Water outlet
5
Water inlet
6
Drain outlet
7
Drain pipe hole (for safety valve)
Number of conductors
AC/DC
required
AC
2
AC
5
AC
2 or 3
DC
2
AC
2
AC
2 or 3
DC
2
AC
2
AC
3+GND
4
5
6
7
Assembly unit
79
Maximum operating
current
200 mA
200 mA
200 mA (a)
(b)
200 mA (a)
200 mA (a)
(b)
200 mA (a)
(c)