Main Components - Immergas MAGIS M4-30 Use And Installation

Block heat pumps
Hide thumbs Also See for MAGIS M4-30:
Table of Contents

Advertisement

Push the grille to the left until it stops, then pull the right border to remove it. You may also invert the procedure. Pay at-
tention not to injure your hands.

9.2 MAIN COMPONENTS

Hydraulic module 4-6 kW and 8-16 kW.
7
5.4
5.1
9
5.2
6
5.5
4-6 kW
Code
Assembly unit
1
Automatic air purge valve
3
Expansion vessel
4
Refrigerant gas pipe
5
Temperature sensors
6
Refrigerant liquid pipe
7
Flow switch
8
Pump
9
Plate heat exchanger
10
Water outlet pipe
11
Pressure relief valve
12
Water inlet pipe
7
1
3
11
4
8
8
3
12
10
12
8-16 kW
Explanation
The residual air in the water circuit will be removed automatically
from the water circuit.
Balances the pressure of the water system.
-
Four temperature sensors determine the temperature of the water
and of the refrigerant at the various points of the water circuit.
5.1-T2B; 5.2-T2; 5.3-T1(optional); 5.4-TW_out; 5,5-TW_in.
-
Detects the water flow rate to protect the compressor and the
water pump in case of insufficient water flow.
Circulates the water in the water circuit.
Transfers the heat of the refrigerant to the water.
-
Prevents overpressure of the water by opening at 3 bar and drain-
ing water from the water circuit.
-
50
1
11
5.4
4
9
10
6
5.5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents