Installation Requirements; Position Of Drain Hole - Immergas MAGIS M4-30 Use And Installation

Block heat pumps
Hide thumbs Also See for MAGIS M4-30:
Table of Contents

Advertisement

7.2 INSTALLATION REQUIREMENTS.

• Check the strength and level of the ground where the unit is installed so that it does not vibrate or make noise during
operation.
• Secure the appliance firmly with anchor bolts according to the foundation drawing in the figure. (Prepare four series of
Φ 10 expansion bolts, nuts and washers easily found on the market).
• Screw the anchor bolts up to 20 mm from the surface of the foundation.
Φ10 Bullone a
Φ10 Expansion
espansione
bolt
Tappetino
anti-urto in
Anti-shock
gomma
rubber mat
Superficie
Solid surface
solida o
or cover
copertura
Φ10 Bullone a
Φ10 Expansion
bolt
espansione
Tappetino
Anti-shock
anti-urto in
rubber mat
gomma
Superficie
Solid surface
solida o
or cover
copertura

7.3 POSITION OF DRAIN HOLE.

Models 4-6 kW
Drain hole
Foro di scarico
Models 18-30 kW
NOTE
An electric heating cable must be installed if the water is not able to flow out due to the cold (Only for models 4-16 kW:
even if the large drain hole is unplugged).
Models 4-16 kW
≥100mm
≥100mm
≥80mm
Basamento in
≥80mm
Concrete base
calcestruzzo
h≥100mm
h≥100mm
Models 18-30 kW
≥100mm
≥100mm
≥80mm
≥80mm
Concrete base h≥100mm
Basamento in
calcestruzzo h≥100 mm
Drain hole
Foro di scarico
Models 8-16 kW
23
Drain hole
Foro di scarico
Questo foro di scarico
This drain hole is
è coperto da un tappo
plugged by a rubber
di gomma. Se il foro di
cap. If the small drain
scarico piccolo non può
hole does that meet the
soddisfare i requisiti di
drainage requirements,
scarico, si può
the large drain hole can
utilizzare
be used at the same
contemporaneamente il
time.
foro di scarico grande.