TEST MODE AND FINAL CHECKS.
The installer must check that the unit works properly after installation.
11.1
FINAL CHECKS.
Before switching on the appliance, read the following recommendations:
• When installation is complete and all the necessary settings have been made, close all the front panels of the unit and put
the unit cover back on.
• The service panel of the electric switchgear can only be opened by an authorised electrician for maintenance.
NOTE
During the initial operation of the unit, the required power could be higher than that indicated on the unit's data
nameplate. This is caused by the compressor which needs 50 hours of operation before reaching regular operation and
stable energy consumption.
TEST OPERATION (MANUAL).
11.2
If necessary, the installer can perform a manual test operation at any time to check proper operation of the air purge, heat-
ing, cooling, domestic hot water heating, see Chap. 10.5.11 Test operation.