Test Mode And Final Checks; Final Checks; Test Operation (Manual) - Immergas MAGIS M4-30 Use And Installation

Block heat pumps
Hide thumbs Also See for MAGIS M4-30:
Table of Contents

Advertisement

Order
Code
number
ADDRESS
16.3
RESET
17.1
HMI SET
HMI ADDRESS
17.2
FOR BMS
17,3
STOP BIT
11

TEST MODE AND FINAL CHECKS.

The installer must check that the unit works properly after installation.
11.1

FINAL CHECKS.

Before switching on the appliance, read the following recommendations:
• When installation is complete and all the necessary settings have been made, close all the front panels of the unit and put
the unit cover back on.
• The service panel of the electric switchgear can only be opened by an authorised electrician for maintenance.
NOTE
During the initial operation of the unit, the required power could be higher than that indicated on the unit's data
nameplate. This is caused by the compressor which needs 50 hours of operation before reaching regular operation and
stable energy consumption.

TEST OPERATION (MANUAL).

11.2
If necessary, the installer can perform a manual test operation at any time to check proper operation of the air purge, heat-
ing, cooling, domestic hot water heating, see Chap. 10.5.11 Test operation.
Status
Reset the address code of the unit.("FF" is an
invalid address code.) After having set the
address, press"UNLOCK" to confirm.
Select the HMI:
0=MAIN, 1=SEC.
Set the HMI address code for BMS
Set the stop bit value
Mini-
Default
mum
FF
0
0
0
1
1
1
1
120
Maxi-
Interval
Unit
mum
definition
15
1
/
1
1
/
16
1
/
2
1
/

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents