Immergas MAGIS M4-30 Use And Installation page 113

Block heat pumps
Hide thumbs Also See for MAGIS M4-30:
Table of Contents

Advertisement

Operation of the unit during preheating of the floor is described in the figure below:
If FLOOR DRYING UP has been selected, after having pressed OK, the following pages will appear:
Use
to scroll to ENTER and press OK. The following page will be displayed:
During floor drying up, only the OK button is valid. When the heat pump is not running, the floor drying up mode is
deactivated when the backup heating source is not available. If you want to deactivate floor drying up, press OK.
The target outlet water temperature during floor drying up is described in the image below:
T1s+dT1s
T1s
ON
OFF
Pump
Pompa
ON
OFF
Compressor
Compressore
t_interval_H
12.2 ASCIUGATURA PAVIMENTO
12.2 FLOOR DRYING UP
T_DRYUP
TEMPO DI RISCALDAMENTO(t_DRYUP)
DURATA(t_HIGHPEAK)
T_HIGHPEAK
T_DRYD
TEMP. TEMPO INATTIVO(t_DRYDOWN)
TEMPERATURA DI PICCO(T_DRYPEAK)
T_DRYPEAK
T_DRYPEAK
TEMP.(T_DRYPEAK)
MODIFICA
ADJUST
12.2 ASCIUGATURA PAVIMENTO
12.2 FLOOR DRYING UP
DATA DI INIZIO
START DATE
CONFERMA
ENTER
MODIFICA
ADJUST
12.3 FLOOR DRYING UP
The unit will operate floor drying up on
01-08-2018
ENTER
113
t
t_firstFH
8
giorni
DAYS
5 giorni
DAYS
5 giorni
DAYS
45°C
15:00
01-01-2019