10.5.5
Temp. Type Setting.
Information on Temp. Type Setting.
The TEMP. TYPE SETTING is used to select whether the water flow temperature or the room temperature is used to control
switching the heat pump on/off.
When the ROOM TEMP. is enabled, the target water flow temperature will be calculated based on the climatic curves.
How to enter the Temp. Type Setting.
Go to MENU>FOR SERVICEMAN>5. TEMP. TYPE SETTING.
Press OK. The following page will be displayed:
If only WATER FLOW TEMP. is set at YES, or only ROOM TEMP. is set at YES, the following pages will be displayed:
If WATER FLOW TEMP. and ROOM TEMP. are set at YES, while DOUBLE ZONE is set NO or YES, the following pages
will be displayed:
In this case, the setting value of zone 1 is T1S, the setting value of zone 2 is T1S2 (the corresponding T1S2 is calculated
based on the climatic curves).
If DOUBLE ZONE is set at YES and ROOM TEMP. is set at NO, while WATER FLOW TEMP. is set at YES or NO, the
following pages will be displayed:
In this case, the setting value of zone 1 is T1S, the setting value of zone 2 is T1S2.
5. TEMP. TYPE SETTING
5 IMPOSTAZIONE TIPO TEMP.
5.1 TEMP. FLUSSO ACQUA
5.1 WATER FLOW TEMP.
5.2 TEMP. AMBIENTE
5.2 ROOM TEMP.
5.3 DOUBLE ZONE
5.3 DUE ZONE
ADJUST
MODIFICA
only WATER FLOW TEMP. YES
solo TEMP. FLUSSO ACQUA SÌ
Homepage (zone 1)
Homepage (zona 1)
Homepage (zone 1)
Homepage (zona 1)
YES
NO
NO
NO
NO
only ROOM TEMP. YES
solo TEMP. AMBIENTE SÌ
2
Additional page (zone 2)
Pagina aggiuntiva (zona 2)
(The double zone is effective)
(La doppia zona è efficace)
2
Additional page (zone 2)
Pagina aggiuntiva (zona 2)
106