Immergas MAGIS M4-30 Use And Installation page 10

Block heat pumps
Hide thumbs Also See for MAGIS M4-30:
Table of Contents

Advertisement

CAUTION
• Do not install the unit in the following places:
- Where there is mineral oil mist, oil spray or vapours. The plastic components could deteriorate and cause detachment
or leakage of water.
- Where corrosive gases are produced (such as sulphurous acid gas). Where the corrosion of copper pipes or welded
parts can lead to refrigerant leaks.
- Where there is machinery that emits electromagnetic waves. The electromagnetic waves can disturb the control
system and cause the appliances to malfunction.
- Where flammable gases could escape, where the carbon fibre or flammable dust is suspended in the air or where
flammable volatile substances are handled such as paint thinners or petrol. These types of gas could cause a fire.
- Where the air contains high levels of salt, like near the ocean.
- Where there is high voltage isolation, like in factories.
- In vehicles or ships.
- Where there are acid vapours or alkalines.
• This appliance can be used by children at least 8 years old and by persons with reduced physical, sensory or mental
capacities or with little experience and knowledge as long as they are supervised or receive instructions on how to use
the appliance safely and understand its risks. Children should not play with the appliance. Cleaning and maintenance
of the utility must not be carried out by children without supervision.
• Make sure that children do not use the product as a toy.
• If the power cable is damaged, it must be replaced by the manufacturer, by a service agent or by just as qualified persons.
• DISPOSAL: Do not dispose of this product as unsorted city waste. This waste must be collected separately for special
treatment. Do not dispose of electrical equipment as city waste; make use of separate collection facilities. Contact your
local government for information on available collection facilities. If the electrical equipment is disposed of in landfills,
the hazardous substances can infiltrate into groundwater and enter the food chain, thus damaging your health and
well-being.
• Check the safety of the area and installation (walls, floors, etc.) without concealed dangers such as water, electricity
and gas.
• Before installation, check whether the power supply of the utility meets the electrical installation requirements of the
unit (including reliable earthing, dispersion and the diameter of the electrical load cable, etc.). If the electrical instal-
lation requirements of the product are not met, the product cannot be installed until this is rectified.
• When several units are installed in a centralised manner, please confirm balancing of the three-phase power load and
do not allow multiple units to be assembled in the same three-phase power supply phase.
• The installed product must be firmly fastened. Use reinforcement measures where necessary.
• To guarantee the safety of the product, please restart the unit at least once every 3 months so that it can perform a
self-inspection.
NOTE
• Information on fluorinated gases
- This unit contains fluorinated gases. For specific information on the type and amount of gas, see the relative label on
the unit. National standards on gas must be complied with.
- Installation, service, maintenance and repair operations on this unit must be carried out by a certified technician.
- The product must be uninstalled and recycled by a certified technician.
- If the system is fitted with a leak detection system, it must be checked at least every 12 months. When a leak check
is carried out on the unit, you are warmly recommended to correctly log all the controls.