Download Print this page

Advertisement

Quick Links

Air conditioner
Installation manual
AC***TXQL*C
DB68-09226A-02

Advertisement

loading

Summary of Contents for Samsung AC TXQL C Series

  • Page 1 Air conditioner Installation manual AC***TXQL*C DB68-09226A-02...
  • Page 2 Contents Safety Information Installation Procedure Extra procedures Appendix Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in countries with separate collection systems) 2 English...
  • Page 3 Safety Information • WARNING • • CAUTION • • WARNING • • • • • • General information • • WARNING • • • • • • • • • English...
  • Page 4 Safety Information Installing the unit Power supply line, fuse or circuit breaker WARNING WARNING IMPORTANT: When installing the unit, always • remember to connect first the refrigerant tubes, then the electrical lines. • • • • • • • • •...
  • Page 5 • Remote control sensor 1.5 m or more 1.5 m or more 300 mm Outdoor Unit Protection wall Sea breeze Stereo Computer etc 200 mm Outdoor Unit Air Guide Duct (This product is not provided by Samsung) • • English...
  • Page 6 Installation Procedure CAUTION C Type • • • D Type • • – E Type – • Outdoor unit dimensions Minimum clearances for the outdoor unit (Unit: mm) When installing 1 outdoor unit (Unit: mm) A Type B Type 2000 300 or 600 or or more...
  • Page 7 When installing more than 1 outdoor unit CAUTION (Unit: mm) • 1500 3000 3000 or more or more or more or more or more WARNING • or more or more [Bar type louver] [Rain resistance louver] or more or more •...
  • Page 8 Installation Procedure CAUTION Wire rope • Plate protection cloth • • Step 2 Fixing the outdoor unit in place • • Optional: Fixing the outdoor unit to a wall with a rack Designed to cut off residual vibration from outdoor unit to rack.
  • Page 9 Step 3 Connecting the power cables, Air conditioning system examples communication cable, and controllers Communication cable Main power Outdoor-to-indoor power cable • cable MCCB Earthing • ELCB • Outdoor Unit Indoor Unit CAUTION • Communication cable Main power Outdoor-to-indoor power cable cable MCCB Earthing...
  • Page 10 Installation Procedure When using ELB for 1 phase and 3 pahse Electrical Power supply component box AC030/036/042/048TXQLEC (1-phase) MCCB 1(L) 2(N) Cable tie Outdoor-to- Main power Communication cable indoor power cable cable AC054/060TXQLGC (3-phase) 1(L) 2(N) L1(R) L2(S) L3(T) The appearance of the unit may be different from the picture depending on the model.
  • Page 11 Main power terminal block specifications • • AC power Communication : M4 screw : M4 screw AC power Communication : M4 screw : M4 screw 1(L) 2(N) L1(R) L2(S) L3(T) 1(L) 2(N) 11.4 10.1 9.95 11.55 10.1 16.3 11.4 Main power cable specifications •...
  • Page 12 Installation Procedure Silence mode controller wiring diagram NOTE • • Outdoor unit CN001 • • CN001 Non-voltage contact • • • Outdoor unit ASSY Control out Model Ssc [MVA] Non-voltage contact English...
  • Page 13 Connecting the outdoor-to-indoor power cable and Indoor unit : 4WAY CST (AC***TN4PEC) the communication cable • Indoor unit : 360CST (AC***TN4FEC) • Indoor Unit Indoor Unit Outdoor Unit Outdoor Unit 1(L) 2(N) L 1(L) 2(N) Cable Cable clamp Cable Cable clamp Communication Outdoor to indoor Main power...
  • Page 14 Installation Procedure Indoor unit : DUCT (AC***TNMPEC, AC***TNHPEC) • • Indoor Unit Indoor Unit F1 F2 1(L) 2(N) Cable clamp Cable clamp Cable tie Outdoor Unit Outdoor Unit 1(L) 2(N) 1(L) 2(N) L1(R) L2(S) L3(T) Cable Cable clamp Cable tie Outdoor to indoor Communication Main power...
  • Page 15 Outdoor-to-indoor power terminal specifications • • Silver solder Nominal Nominal Standard Standard Standard Standard Allowance Allowance Allowance Min. Min. Max. Allowance Min. dimensions for dimensions for dimension dimension dimension dimension (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) cable (mm²) screw (mm) (mm) (mm)
  • Page 16 Installation Procedure Outdoor-to-indoor power and communication cables specifications • • Indoor unit : 360 CST (AC***TN4FEC), 4WAY CST (AC***TN4PEC) (Unit: mm) Indoor power supply Power cable Power supply Max/Min (V) Indoor power cable Communication cable • Indoor unit : DUCT (AC***TNMPEC, AC***TNHPEC) Indoor power supply Power supply Max/Min (V) Indoor power cable...
  • Page 17 • Method 2 Method 1 Insulation tape Insulation tape Compression dimension CAUTION • • • Method 1 Method 2 Compress it 4 times. Compress it 4 times. WARNING 5 mm 5 mm • – Method 2 Method 1 Contraction tube Contraction tube Method 2 Method 1...
  • Page 18 Installation Procedure Step 5 Connecting the refrigerant pipe Make at least one round: It will reduce noise and vibration Max. height Applicable difference Main After Items outdoor unit between outdoor connectiong pipe (L1) the pipes, block models and indoor units the part (h1) Maximum...
  • Page 19 the pipes Pipe cutter 90° Uneven Damaged Cracked Correct Inclined thickness surface CAUTION Pipe Oblique Rough Burr • • Step 7 Connecting up and removing air R 0.4 to 0.8 mm in the circuit CAUTION Flare • Pipe Flare Outer diameter Flare dimension Depth (A) English...
  • Page 20 Installation Procedure • AC018/024TXQLEC Outdoor Unit A (Gas) B (Liquid) A(Gas) B(liquid) Vacuum pump • AC030/036/042/048/054/060TXQL*C Outer Diameter (D) Torque (N m) Outdoor Unit CAUTION Vacuum Pump • A(Gas) B(liquid) English...
  • Page 21 Step 8 Adding refrigerant (R-410A) • • • Calculating the quantity of refrigerant • to add • • AC018/024TXQLEC • CAUTION • • • AC030/036/042/048/054/060TXQL*C NOTE • English...
  • Page 22 Installation Procedure Step 9 Performing the gas leak test LEAK TEST WITH NITROGEN (before opening valves) Liquid side stop valve(service port) Indoor Unit Gas side stop valve(service port) LEAK TEST WITH R-410A (after opening valves) Balance Outdoor Unit Vacuum pump •...
  • Page 23 Step 10 Connecting the drain hose to • the outdoor unit Drain cap (3EA) Drain plug (1EA) • • Step 11 Insulating the refrigerant pipes 80 mm 13 mm No gap • Drain cap (4EA) Drain plug (1EA) NOTE • •...
  • Page 24 Installation Procedure Step 12 Checking the earthing • • • • Insulation Type (Heating/Cooling) • High Standard humidity Pipe size Pipe Remarks [Less than (mm) • [over 30°C, 30°C, 85%] 85%] EPDM, NBR NOTE (mm) • Carbon plastic Steel core Terminal M4 PVC-insulated To grounding screw...
  • Page 25 • • trial operation • • • • Display Key Push type Mode SEG 1 SEG 2SEG 3 English...
  • Page 26 Installation Procedure short Display contents SEG1 SEG2 SEG3 SEG4 Unit push Display contents SEG1 SEG2 SEG3 SEG4 After short push 1 After short K4 long push 2 push After short push 3 After short push 4 English...
  • Page 27 Option Input SEG1 SEG2 SEG3 SEG4 Function item unit • Step for Silence – mode Type of Silence mode – Not applicable – Not applicable • Current restriction • • CAUTION • • Option Input SEG1 SEG2 SEG3 SEG4 Function item unit –...
  • Page 28 Extra Procedures Extra Procedures Pumping down refrigerant • WARNING • B(liquid) A(Gas) – Relocating the indoor and outdoor units Pumping down refrigerant NOTE • • A(Gas) B(Liquid) English...
  • Page 29 Using the stop valve NOTE • Opening the stop valve • Tightening torque for charging port cap (Refer to the table) Closing the stop valve Charging Core R-22 : Thread of the screw - 7/16-20UNF R-410A : Thread of the screw - 1/2-20UNF Spindle CAUTION •...
  • Page 30 Appendix Appendix Troubleshooting Error Meaning Remarks Code English...
  • Page 31 Error Meaning Remarks Code English...
  • Page 32 Appendix Packing and unpacking guide Outdoor unit Cushion top Outdoor Unit Packing Case Assy Cushion Base • • English...
  • Page 33 Cushion top Outdoor unit Packing case Assy Cushion Base • • English...
  • Page 34 Appendix Outdoor unit Cushion-top Outdoor unit 4 screws Packing case Wood palette • • English...
  • Page 35 Product specification OUTDOOR UNIT AC018TXQLEC AC024TXQLEC AC036TXQLEC MODEL INDOOR UNIT AC018TN4FEC AC024TN4FEC AC036TN4FEC CLIMATE CLASS COOLING RATED CAPACITY HEATING (H1) RATED VOLTAGE & FREQUENCY COOLING RATED CURRENT HEATING (H1) COOLING RATED POWER INPUT HEATING (H1) COOLING EER / COP HEATING (H1) REFRIGERANT kg, TYPE for 2,000 Hr...
  • Page 36 Appendix OUTDOOR UNIT AC036TXQLEC AC048TXQLEC AC018TXQLEC MODEL INDOOR UNIT AC036TN4PEC AC048TN4PEC AC018TNMPEC CLIMATE CLASS COOLING RATED CAPACITY HEATING (H1) RATED VOLTAGE & FREQUENCY COOLING RATED CURRENT HEATING (H1) COOLING RATED POWER INPUT HEATING (H1) COOLING EER / COP HEATING (H1) REFRIGERANT kg, TYPE for 2,000 Hr...
  • Page 37 OUTDOOR UNIT AC042TXQLEC AC054TXQLGC AC060TXQLGC MODEL INDOOR UNIT AC042TNMPEC AC054TNMPEC AC060TNHPEC CLIMATE CLASS COOLING RATED CAPACITY HEATING (H1) RATED VOLTAGE & FREQUENCY COOLING RATED CURRENT HEATING (H1) COOLING RATED POWER INPUT HEATING (H1) COOLING EER / COP HEATING (H1) REFRIGERANT kg, TYPE for 2,000 Hr ANNUAL ENERGY...