Download Print this page
Elkay LVRCDWS A Series Installation And Use Manual

Elkay LVRCDWS A Series Installation And Use Manual

Factory prep ezh2o bottle filling station and cooler

Advertisement

Quick Links

LVRCDWS*A, *2A LVRCTLDDWSC*A, *2A LVRC8WS*1A, *2A, *3A LVRCTL8WSC*1A, *2A, *3A
INSTALLATION and USE MANUAL
LVRC8WS, LVRC8WSJO, LVRCTL8WS, LVRCTL8WSJO, Factory Prep
ezH2O
Bottle Filling Station and Cooler
®
IMPORTANT
THIS IS AN INDOOR APPLICATION ONLY.
ALL SERVICE TO BE PERFORMED BY AN
Model LVRC8WS
AUTHORIZED SERVICE PERSON.
Model LVRCTL8WS
Page 1
98980C (REV. K - 08/17)

Advertisement

loading

Summary of Contents for Elkay LVRCDWS A Series

  • Page 1 LVRCDWS*A, *2A LVRCTLDDWSC*A, *2A LVRC8WS*1A, *2A, *3A LVRCTL8WSC*1A, *2A, *3A INSTALLATION and USE MANUAL LVRC8WS, LVRC8WSJO, LVRCTL8WS, LVRCTL8WSJO, Factory Prep ezH2O Bottle Filling Station and Cooler ® IMPORTANT THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN Model LVRC8WS AUTHORIZED SERVICE PERSON.
  • Page 2: Tools Required

    LVRCDWS*A, *2A LVRCTLDDWSC*A, *2A LVRC8WS*1A, *2A, *3A LVRCTL8WSC*1A, *2A, *3A Note: Danger! Electric shock hazard. Disconnect power before servicing unit. Uses HFC-134A refrigerant TOOLS REQUIRED BUT NOT PROVIDED: SAFETY GLASSES GLOVES ELECTRIC DRILL 3/4” WRENCH OR CRECENT WRENCH UTILITY KNIFE TAPE MEASURE PENCIL CENTER PUNCH...
  • Page 3 LVRCDWS*A, *2A LVRCTLDDWSC*A, *2A LVRC8WS*1A, *2A, *3A LVRCTL8WSC*1A, *2A, *3A Single Rough-In Fig. 1 Page 3 98980C (REV. K - 08/17)
  • Page 4 LVRCDWS*A, *2A LVRCTLDDWSC*A, *2A LVRC8WS*1A, *2A, *3A LVRCTL8WSC*1A, *2A, *3A Single Rough-In Fig. 1 98980C (REV. K- 08/17) Page 4...
  • Page 5 LVRCDWS*A, *2A LVRCTLDDWSC*A, *2A LVRC8WS*1A, *2A, *3A LVRCTL8WSC*1A, *2A, *3A MOUNTING TOP COVER SCREWS BOTTLE FILLER MOUNTING BRACKET FOR FASTENING UNIT MOUNTING SCREWS TO WALL DO NOT REMOVE MOUNTING SCREWS DO NOT REMOVE NOTE: TRIM PLATES MUST BE INSTALLED ON THE INSIDE OF THE BOTTLE FILLER SIDE PANEL SLOTS.
  • Page 6 LVRCDWS*A, *2A LVRCTLDDWSC*A, *2A LVRC8WS*1A, *2A, *3A LVRCTL8WSC*1A, *2A, *3A REMOVAL OF BOTTLE FILLER FOR SERVICING 1) Turn off the water supply to the Water Cooler(s). Unplug and/or turn off Circuit Breaker to Cooler(s) and Bottle Filler. NOTE: the Lower Front Panel of the cooler(s) may need to be removed.
  • Page 7 LVRCDWS*A, *2A LVRCTLDDWSC*A, *2A LVRC8WS*1A, *2A, *3A LVRCTL8WSC*1A, *2A, *3A BF9 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE SETTING UNIT TYPE 1) To verify the software program of the control board the 1) Depress the program button for approximately 2 seconds unit will need to be shut down and restarted.
  • Page 8 LVRCDWS*A, *2A LVRCTLDDWSC*A, *2A LVRC8WS*1A, *2A, *3A LVRCTL8WSC*1A, *2A, *3A BF11 - BF12 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE Continued from below: 1) To verify the software program of the control board the unit will 2) When the display changes to “SETTINGS”, depress the button again. need to be shut down and restarted.
  • Page 9: Replacement Part Kits

    REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.481 PRINTED IN U.S.A. ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 • www.elkay.com Page 9 98980C (REV. K - 08/17)