THOMSON DFT-6900 User Manual

THOMSON DFT-6900 User Manual

Battery activator

Advertisement

Quick Links

DFT-6101 Battery Impedance Tester Instruction Manual
DFT-6900 Battery Activator
Users Manual
THOMSON TECH CO LTD
www.thomsontesting.com

Advertisement

Table of Contents
loading

Summary of Contents for THOMSON DFT-6900

  • Page 1 DFT-6101 Battery Impedance Tester Instruction Manual DFT-6900 Battery Activator Users Manual THOMSON TECH CO LTD www.thomsontesting.com...
  • Page 2: Table Of Contents

    DFT-6900 Battery Activator Instruction Manual Table of Contents Precaution ................2 Chapter 1 Overview ..............3 1.1 Applications ................................3 1.2 Functions ................................3 1.3 Characteristics ............................... 3 1.4 Working Principle ..............................4 1.5 Technical Specifications ............................4 1.6 Main Parts ................................5 1.7 Operation Instruction ............................
  • Page 3: Precaution

    After testing battery, there is high temperature inside the main body of DFT-6900. Therefore, please keep the unit powered on to evaporate the heat for at least 5 minutes. Do not shut down the unit right after testing. This is very important ensure the good performance of all electronic parts inside the main body.
  • Page 4: Chapter 1 Overview

    Chapter 1 Overview 1.1 Applications DFT-6900 is a compact unit for daily maintenance of single cell, especially for old cells. It plays three roles: charge, Discharge and activator, which will facilitate your maintenance for batteries. These three functions could be used individually or comprehensively.
  • Page 5: Working Principle

    DFT-6900 Battery Activator Instruction Manual generate corresponding data reports. 1.4 Working Principle The working principle of the Tester is to control the single-chip microcomputer by operating the keyboard, and LCD displays the operation menu and test control results. The Tester provide charge/Discharge and monitoring function, also user can save one set of curve for each battery charge, separate discharge and battery activation, which greatly improves the user's use efficiency.
  • Page 6: Main Parts

    DFT-6900 Battery Activator Instruction Manual 1.6 Main Parts The main unit comes with two current clamps (one red and one black) and one voltage detection line. Connect the three-pin terminal of the voltage detection line to the “voltage detection” terminal on the back panel of the main unit.
  • Page 7: Chapter 2 Functions & Operations

    DFT-6900 Battery Activator Instruction Manual Chapter 2 Functions & operations Power On Turn on the power switch on the back of the Tester, LCD displaying the model and version No. Wait a moment to automatically enter the main interface. The main interface is as follows: 2.1 Discharge...
  • Page 8: Charge

    DFT-6900 Battery Activator Instruction Manual 2.2 Charge Click “Charge” to enter parameters setting interface. It is necessary to set six parameters: battery number, battery type, rated capacity, cutoff voltage, charge current, and charge duration. Set the discharge parameters and press the [Start] key to enter the charging status indication interface.
  • Page 9: Activator

    DFT-6900 Battery Activator Instruction Manual 3 Activator Click “Activator” to enter parameters setting interface 2.3.1 Activator Setting Interface In the activation setting interface, the battery number, battery type, rated capacity, discharge voltage limit, charge limit voltage, and number of cycles (the number of times is not more than 10) are displayed. As shown below: Enter the battery activation interface.
  • Page 10: Data Transfer

    DFT-6900 Battery Activator Instruction Manual display the measurement result. View Data Discharge Data Activating Data 2.4.2 Data Transfer In the data management menu, click the [U-disk], the data will be transferred. Please insert the U-disk first, and the green "U" symbol will be displayed in the upper right corner of the menu.
  • Page 11: Data Delete

    DFT-6900 Battery Activator Instruction Manual 3. When performing the operation, please insert the U-disk first, and wait until the indicator light of the “U-disk” is no longer flashing before other operations. 4. Do not plug or unplug the U-disk while the U-disk is reading or written.
  • Page 12: Language

    DFT-6900 Battery Activator Instruction Manual The figure shows below: Click the [Update] button to enter the software update program. The meter automatically restarts and loads the update file of the U-disk to Tester. After the software update is completed, the Tester enters the boot interface and can perform normal operation 2.5.3 Language...
  • Page 13: Chapter 3 Daily Maintenance

    DFT-6900 Battery Activator Instruction Manual Chapter 3 Daily Maintenance 3.1 Clean &Maintenance 3.1.1 Mani Unit Maintenance/Clean Clean the main unit and its accessories with damp cloth and a mild soap. Do not use abrasives, solvents, or alcohol, as they can deform or discolor the Tester and the accessories.
  • Page 14: Chapter 4 Faq

    DFT-6900 Battery Activator Instruction Manual Chapter 4 FAQ  Do not start up Check power supply wiring  No signals after the Tester is on The Tester may not be properly connected. If so, make sure it is well connected.
  • Page 15 DFT-6900 Battery Activator Instruction Manual The U-disk cannot be detected after it is inserted to the PC The U-disk may not be well inserted. If so, reinsert it correctly. The U-disk may not be in FAT format. If so, format the U-disk.

Table of Contents