THOMSON DFT-6102 User Manual

Battery conductance tester

Advertisement

Quick Links

DFT-6102
Battery Conductance Tester
Users Manual
THOMSON TECH CO LTD
www.thomsontesting.com

Advertisement

Table of Contents
loading

Summary of Contents for THOMSON DFT-6102

  • Page 1 DFT-6102 Battery Conductance Tester Users Manual THOMSON TECH CO LTD www.thomsontesting.com...
  • Page 2: Table Of Contents

    2.6.3 Test the waveform ..........................9 2.6.4 Software Version information ......................10 Chapter 3 Tester Main Parts Structure ..........11 3.1. Package List ..............................11 3.2. DFT-6102 Host ............................11 3.3 Testing Line ..............................12 3.4 Host Charger ..............................12 3.5 Data Line ..............................13 3.6 Box................................13...
  • Page 3: Chapter 1 Overview

    Conductance DFT-6102 Battery Tester Instruction Manual Chapter 1 Overview 1.1. Purpose The battery Conductance Tester adopts the most advanced AC discharge test method, which can accurately test the voltage and conductance at both ends of the battery, and then judge the advantages and disadvantages of the battery capacity and technical status.
  • Page 4: Advantages Of The 4-Line Test Clamp

    Conductance DFT-6102 Battery Tester Instruction Manual hazards. (5) The tester itself can store a large amount of test data, and can be conclusive query and analysis on the tester, and the battery test data can also be exported to the computer software with a U disk to generate charts and curves for analysis.
  • Page 5: Function

    Conductance DFT-6102 Battery Tester Instruction Manual 1.5. Function Item Description The conductance Test and performance evaluation of single cell batteries, String batteries, Battery Test batteries + connection conductance (optional) Data Open and play back the data records, dump the U-disk, delete and other operations, and management format the data records at the same time.
  • Page 6: Chapter 2 Operation Instructions

    Conductance DFT-6102 Battery Tester Instruction Manual Chapter 2 Operation instructions 2.1. The Tester Power on/off There is a power switch on the left side of the tester, dial the upper end to Power and the down end to Power off. Refer to Boot the main menu as follows: The main menu consists of three parts: upper, middle and lower.
  • Page 7: Optional) Test Instructions With Connection Conductance's (Same Test In Strings)

    Conductance DFT-6102 Battery Tester Instruction Manual Setting interface Testing interface End interface (Optional) Test instructions with connection conductance’s (same Test in Strings) 2.2.1 3-wire & 3-clamp simultaneous Test. The red clamp is connected to the connection conductance, the red and...
  • Page 8: Custom Standard Parameters

    Conductance DFT-6102 Battery Tester Instruction Manual 2.3.1 Custom standard parameters Click the "Unit" button on the right side of "Battery Voltage", pop up the custom parameter dialog window, set the custom parameters, click "Save". After saving, you can see that the "V" of the button changes to "Custom x", indicating that the customization was successful.
  • Page 9: Clock Settings

    Conductance DFT-6102 Battery Tester Instruction Manual Data management interface Open recording interface 2.5. Clock settings When operating by using the touch screen, you can tap the input or key directly, and the input number can be achieved by scrolling up and down. If you use the keyboard to operate, then the "TAB" key toggles the input "↓"...
  • Page 10: File Management

    Conductance DFT-6102 Battery Tester Instruction Manual 2.6.1 File management The tester can upgrade the system software through the U-disk, first put the upgraded software image file into the U disk, Power Off; then connect the U-disk and the tester through the OTG cable, press back key to boot and Power-on, and then wait for the upgrading, the interface prompts the upgrade progress, and automatically starts to the running interface after the upgrade is successful.
  • Page 11: Software Version Information

    Conductance DFT-6102 Battery Tester Instruction Manual 2.6.4 Software Version information Double-click the "Version Info" menu item under the system management menu page to view the teetered system software version and Tester series number (S/N), as shown in the figure:...
  • Page 12: Chapter 3 Tester Main Parts Structure

    DFT-6102 Host Test clamp (or Probe) 1kit Host Charger 1kit U-disk Data line User manual Packing list 3.2. DFT-6102 Host The host is used for field testing by operation, calculation, test results display, Storage and other use. (Quantity: 1 unit)
  • Page 13: Testing Line

    Conductance DFT-6102 Battery Tester Instruction Manual 3.3 Testing Line Testing Line is either-or of Testing Line clamp or Testing Line probe 3.4 Host Charger . (Quantity: 1pc) Host Charger is for Host inside battery charging...
  • Page 14: Data Line

    Conductance DFT-6102 Battery Tester Instruction Manual 3.5 Data Line Data Line is for data communication from host to PC by U-disk. 3.6 Box Used to pack the main host and accessories. (Quantity: 1pcs)
  • Page 15: Chapter 4 Tester Storage Instructions

    Conductance DFT-6102 Battery Tester Instruction Manual Chapter 4 Tester storage instructions 4.1. Storage hardware Tester & U-disk can both store data including boot screen data, Test data & etc 4.2. Data Type There are several types of tester data:: 1) Boot screen data: Logpic.BMP. (Length X width 272X480).
  • Page 16: Chapter 5 Routine Maintenance

    Conductance DFT-6102 Battery Tester Instruction Manual Chapter 5 Routine maintenance 5.1. Cleaning maintenance (1) Cleaning and maintenance of the host Wash the main unit with a soft damp cloth and a mild detergent. Please do not use abrasive type. Dissolving cleaners or alcohol, etc., so as not to scratch the host panel or damage the text on the host.

Table of Contents