Immergas CAESAR 14 Star Technical Documentation Manual page 14

Instantaneous wall-hung room sealed fan-assisted water heater
Table of Contents

Advertisement

Technical Documentation
CAESAR Star electrical circuit.
Operation.
When master switch (S4) is in ON position, it powers
the low-voltage circuit and enables appliance
operation.
If hot water is run the flow measuring device (B2) trips
and this gives the signal for burner ignition.
Afterwards, if the temperature detected by the d.h.w.
NTC sensor (B1) is below that set on the control panel
by means of the d.h.w. potentiometer (S4) the board
starts the fan (M1) and commands relay K1.
The consequent closing of the fume pressure switch
(S3) results in the adjustment circuit powering relay
K2.
This way the board ignition circuit is enabled (IGNITION
SECTION) which first of all commands the ignition/
detection electrode (E1) and then excites relay K3.
With a signal from the overheating thermostat (E3) and
limit thermostat (E2), closing of relay K3 contact powers
both main coils of gas valve (Y1).
Burner ignition is detected by ignition/detection
electrode (E1).
STCS ed 07/02
MAINS
LOW
VOLTAGE
VOLT.
IGNITION
SECTION
14
Technical Documentation
COMMAND LOGIC MICROPROCESSOR
CAESAR Star