Immergas CAESAR 14 Star Technical Documentation Manual page 11

Instantaneous wall-hung room sealed fan-assisted water heater
Table of Contents

Advertisement

Technical Documentation
Technical Documentation
Vertical concentric slot-in kit Ø 60/100.
The exhaust pipe (Ø 60 mm) is fitted inside the
extraction pipe (Ø 100 mm).
Connection to the boiler is by means of a flange (2)
which, by means of the necessary extensions, must
be connected to the extraction and exhaust end piece
60/100 (5) with aluminium tile.
The maximum overall length allowed is 4.7 straight
vertical metres.
Ø 80/80 slot-in separator kit.
The pipes both have a diameter of 80 mm.
Connections to the boiler are by means of two special
flanges for exhaust (4) from central union and extrac-
tion (3) from one of the two side holes.
The maximum length allowed (extraction + exhaust)
is 33 straight horizontal metres and 41 straight ver-
tical metres.
To avoid problems of condensation, the exhaust pipe
should be restricted to a max of 5 m.
STCS ed 07/02
11
CAESAR Star