ENLZSTL8WS_1G
Enhanced
INSTALLATION & USE MANUAL
LZ
Series Bottle Filling Stations & Coolers
* Versatile cooler design allows units to be installed either left-hand high and right-hand low or left-low and right high.
Basin change may be required. See desired rough-in to help determine if the basin change is necessary.
Page 1
1000004543 (Rev. A - 10/18)

Advertisement

loading

Summary of Contents for Elkay LZ Series

  • Page 1 ENLZSTL8WS_1G Enhanced INSTALLATION & USE MANUAL Series Bottle Filling Stations & Coolers ™ * Versatile cooler design allows units to be installed either left-hand high and right-hand low or left-low and right high. Basin change may be required. See desired rough-in to help determine if the basin change is necessary. Page 1 1000004543 (Rev.
  • Page 2 ENLZSTL8WS_1G FIG. 1 1000004543 (Rev. A - 10/18) Page 2...
  • Page 3 ENLZSTL8WS_1G FIG. 2 Page 3 1000004543 (Rev. A - 10/18)
  • Page 4 ENLZSTL8WS_1G FIG. 3 1000004543 (Rev. A - 10/18) Page 4...
  • Page 5 ENLZSTL8WS_1G FIG. 4 Page 5 1000004543 (Rev. A - 10/18)
  • Page 6 ENLZSTL8WS_1G HANGER BRACKET INSTALLATION 1) Remove hanger bracket fastened to back of cooler by removing one (1) screw 2) Mount the hanger bracket as shown in Figures 1,2,3, or 4 (Pages. 2-5) NOTE: Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor hanger securely to wall using all six (6) 1/4 in.
  • Page 7 ENLZSTL8WS_1G Secure cooler frame to wall by installing (2) screws and washers (not supplied). Para fijar la estructura del bebedero a la pared, instale (2) tornillos y arandelas (no se proporcionan). Fixer le bâti de la fontaine à eau fraîche au mur à l’aide de deux (2) vis et rondelles (non fournies). FIG.
  • Page 8 ENLZSTL8WS_1G Fig. 7 Connect the bottle filler electrical harness Fig. 6 MOUNTING BOLT HOLES (6) WALL MOUNTING PLATE BOTTLE FILLING UNIT Fig. 8 1000004543 (Rev. A - 10/18) Page 8...
  • Page 9 ENLZSTL8WS_1G BRACKET & SCREWS SOPORTE Y TORNILLOS Fig. 9 Fig. 10 SUPPORT ET VIS 115V Refrigerated Wiring Diagram with Alpha/Numeric Display Fig. 11 Superseal Fitting Assembly OPERATION OF QUICK CONNECT FITTINGS OPERATION OF QUICK CONNECT FITTINGS SIMPLY PUSH IN SIMPLY PUSH IN TUBE IS SECURED PUSH IN COLLET TUBE IS SECURED...
  • Page 10 ENLZSTL8WS_1G INSTRUCTIONS TO MOVE THE BOTTLE FILLER & BASIN TO THE LEFT SIDE (NON-REFRIGERATED) FOR ALTERNATE MOUNTING VERSATILE BI-LEVEL Fig. A Fig. B Using a 5/16" socket, remove the (4) screws from the bottom of each cooler ONLY move the filler panel and j-clip Using a #T20 (6 point star bit), to remove the wrappers.
  • Page 11 ENLZSTL8WS_1G Refrigerated Cooler side: Carefully lift and tip the shroud/basin assembly off of the cooler frame. Only disconnect the (2) black wires coming from the shroud assembly that go to the solenoid valve and to the cold control. Disconnect the water line at the solenoid valve.
  • Page 12 ENLZSTL8WS_1G INSTRUCTIONS CONTINUED... CONTINUACIÓN DE LAS INSTRUCCIONES... INSTRUCTIONS - SUITE... Left Hand Wrapper (Low Side) 1) Remove existing wrapper by removing the (4) screws from bottom. 2) Clip cover plate, sliding until plate sits flush with the wall. 3) Re-install wrapper with (4) screws. 4) Dispose of unused trim piece.
  • Page 13 ENLZSTL8WS_1G Versatile Wrapper and Trim Kit Installation Instructions Left Hand Wrapper (High Side) Right Hand Wrapper (Low Side) 1) Remove existing wrapper by removing the (4) screws 1) Remove existing wrapper by removing the from bottom. (4) screws from bottom. 2) Screw trim piece to wrapper with (2) screws (provided) 2) Clip cover plate, sliding until plate sits flush 3) Re-install wrapper with (4) screws.
  • Page 14 ENLZSTL8WS_1G PLUMBING DIAGRAMS VERSATILE BI-LEVEL Bottle Filler Drain Bottle Filler Drain Bottle Filler Drain Bottle Filler Drain 1000004543 (Rev. A - 10/18) Page 14...
  • Page 15 ENLZSTL8WS_1G Basin Locknut BUBBLER DETAIL Fig. 15 NOTE: When installing replacement bubbler and pedestal, tighten nut only to hold parts snug in position. Do Not Overtighten. Filter Label Location Fig. 14 Fig. 16 WATERSENTRY Filter Detail ® WATERSENTRY FILTER PARTS LIST ®...
  • Page 16 ENLZSTL8WS_1G Service Instructions Refrigerated Unit Lower and Upper Shroud To access the refrigeration system and plumbing connections, remove four screws from bottom of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars, regulator, solenoid valve or other components located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires and water tube.
  • Page 17 ENLZSTL8WS_1G Page 17 1000004543 (Rev. A - 10/18)
  • Page 18 ENLZSTL8WS_1G Pictured is unit only without bottle filler. Note: Danger! Electrical shock hazard. Disconnect power before servicing unit. Uses HFC-134A refrigerant Usa refrigerante HFC-134A 14, 29 Utilise du fluide frigorigéne HFC-134A See Fig. 9 See Fig. 9 22, 33 Fig. 18 1000004543 (Rev.
  • Page 19 Haz de cables: Paso de la tarja hacia la LlB Faisceau câbles - Alim. fontaine à RB 1000001981 Nameplate - Elkay Filtered Placa de identificación: Elkay con filtro Plaque signalétique - Elkay à filtre 1000001982 Nameplate - Elkay Non-Filtered Placa de identificación: Elkay sin filtro Plaque signalétique - Elkay sans filtre...
  • Page 20: Fcc Compliance Statement

    INFORMATIONS POUR LE SERVICE PAR NUMERO SANS FRAIS 1.800.260.6640 PRINTED IN U.S.A. IMPRESO EN LOS E.E.U.U. ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 • www.elkay.com IMPRIMÉ AUX É.-U. 1000004543 (Rev. A - 10/18)