Summary of Contents for Elkay VRCTLDDWSC A Series

  • Page 1 (L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A INSTALLATION and USE MANUAL VRC8TLWS™ Series Water Coolers with ezH2O Bottle Filling Stations ® Refrigeradores de agua serie VRCTL8WS™ con estaciones de llenado de botellas ezH2O ® Les refroidisseurs d’eau de la série VRCTL8WS™ avec des stations de remplissage de bouteilles ezH2O ®...
  • Page 2: Tools Required

    (L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A HERRAMIENTAS NECESARIAS OUTILS NÉCESSAIRES TOOLS REQUIRED PERO NO SUMINISTRADO: MAIS NON FOURNI: BUT NOT PROVIDED: SAFETY GLASSES LENTES DE SEGURIDAD LUNETTES DE PROTECTION GLOVES GUANTES GANTS ELECTRIC DRILL TALADRO ELÉCTRICO PERCEUSE ÉLECTRIQUE 3/4”...
  • Page 3 (L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A Note: Danger! Electric shock hazard. Disconnect power before servicing unit. Nota: peligro! Peligro de descarga eléctrica. Desconecte antes de reparar la unidad. Remarque : Danger ! Risque d'électrocution. Débrancher avant de réparer l'appareil. Pictured is unit only without bottle filler.
  • Page 4 (L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A FIG. 2 98982C (Rev. T - 01/19) Page 4...
  • Page 5 (L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A FIG. 3 Page 5 98982C (Rev. T - 01/19)
  • Page 6 (L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A MOUNTING TOP COVER SCREWS BOTTLE FILLER MOUNTING BRACKET FOR FASTENING UNIT MOUNTING SCREWS TO WALL DO NOT REMOVE NOTE: TRIM PLATES MUST BE INSTALLED ON THE INSIDE OF THE BOTTLE FILLER SIDE PANEL SLOTS.
  • Page 7 (L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A REMOVAL OF BOTTLE FILLER FOR SERVICING 1) Turn off the water supply to the Water Coolers. Unplug and/or turn off Circuit Breaker to Cooler(s) and Bottle Filler. NOTE: the Lower Front Panel of the coolers may need to be removed.
  • Page 8 (L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A IMPORTANT IMPORTANTE IMPORTANT ALL SERVICE TO BE PERFORMED BY AN TODO EL SERVICIO DEBERÁ SER EFECTUADO POR UNA TOUT ENTRETIEN DOIT ÊTRE EFFECTUÉ PAR UN AUTHORIZED SERVICE PERSON PERSONA DE SERVICIO AUTORIZADA REPRÉSENTANT AUTORISÉ...
  • Page 9 (L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A 13 (8) 39 (TL) 40 (TLR) (Items 18 & 24 also used on the LH unit) 5, 7 FIG. 9 (Refrigerated side shown) Page 9 98982C (Rev. T - 01/19)
  • Page 10 (L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A Drain Pad Kit 98999C FIG. 10 (Bottle Filler side shown) 98982C (Rev. T - 01/19) Page 10...
  • Page 11 (L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A FIG. 11 Filter Installation Detail Detalle de instalación del filtro Détail de l’installation du filtre Basin Estanque Bassin FIG.12 VANDAL RESISTANT BUBBLER DETAIL DETALLE DEL GRIFO RESISTENTE AL VANDALISMO DESCRIPTION DU BARBOTEUR RESISTANT AU VANDALISME Item No.
  • Page 12 (L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A WATERSENTRY PLUS FILTER PARTS LIST ® ITEM PART NO. DESCRIPTION 51300C Filter Assy-3000 Gallon (Single) 51300C_12PK Filter Assy-3000 Gallon (12 Pack) 98926C Kit-Filter Head Fittings-includes John Guest Fittings Assy-Filter Head & Brkt includes Filter Head/ 1000003563 Mtg Brkt/John Guest Ftgs/Screws FIG.
  • Page 13 (L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A TWO PIN JUMPER REMOTE RESET BUTTON FOR MICRO SWITCH ACTIVATION REMOTE RESET BUTTON RESET BUTTON MICRO SWITCH NORMALLY OPEN TWO PIN CONNECTOR FOR REMOTE RESET BUTTON N .C N .O C OM TWO PIN CONNECTOR FOR MICRO SWITCH...
  • Page 14 (L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A BF9 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE SETTING UNIT TYPE 1) To verify the software program of the control board the 1) Depress the program button for approximately 2 seconds unit will need to be shut down and restarted.
  • Page 15 (L)VRCTLDDWSC*A, *2A VRCTLRDDWSC*A, *2A , (L)VRCTL8WSC*1A, *2A, *3A, VRCTLR8WSC*1A, *2A, *3A BF11 - BF12 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE Continued from below: 1) To verify the software program of the control board the unit will 2) When the display changes to “SETTINGS”, depress the button again. need to be shut down and restarted.
  • Page 16 NÚMERO GRATIS DE SERVICIO 1.800.260.6640 IMPRIMÉ AUX É.-U. INFORMATIONS POUR LE SERVICE PAR NUMERO SANS FRAIS 1.800.260.6640 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 • www.elkay.com 98982C (Rev. T - 01/19) Page 16...