Drive Pure Expressions RTLBP0200 Instruction Manual

Drive Pure Expressions RTLBP0200 Instruction Manual

Electric breast pump

Advertisement

Quick Links

P ure
expressions
D U A L C H A N N E L
E L E C T R I C B R E A S T P U M P
Item # RTLBP0200
I N S T R U C T I O N
M A N U A L

Advertisement

Table of Contents
loading

Summary of Contents for Drive Pure Expressions RTLBP0200

  • Page 1 P ure expressions ™ D U A L C H A N N E L E L E C T R I C B R E A S T P U M P Item # RTLBP0200 I N S T R U C T I O N M A N U A L...
  • Page 3: Indications For Use

    Indications for Use The Pure Expressions™ breast pump is intended to express and collect milk from lactating women and maintain the ability of lactation to complement breast feeding. The device is intended for a single user only. Descriptions Pure Expressions is a double electric or battery-operated breast pump that is to be used when a baby would normally be breast feeding, which is multiple times daily.
  • Page 4: Parts Guide

    Parts Guide 1. Breast Shield (2) 9. Double-Connector Cap 2. Valve (2) 10. Collector 3. Membrane (2) 11. Pump Unit 4. 4-Ounce Bottle (2) 12. A/C Adapter 5. Bottle Stand (2) 13. Bottle Cap (2) 6. Single-Connector (2) 14. Nipple 7.
  • Page 5: Symbol List

    Instructions for Use Guide. REFERENCE: Refer to the Instructions for Use Guide. SERIAL NUMBER: Information is located on the device. MANUFACTURED FOR: Medical Depot (DBA Drive Medical) 99 Seaview Blvd. Port Washington, NY 11050 Tel: (866) 694-5085 | Fax: (516) 998-4601 Website: www.drivemedical.com...
  • Page 6: Warnings And Precautions

    Warnings and Precautions Basic safety precautions should be taken when using electrical products, especially around children. Warning: If you are a mother who is infected with Hepatitis B, Hepatitis C or Human Immunodeficiency Virus (HIV), pumping breast milk will not reduce or remove the risk of transmitting the virus to your baby through your breast milk.
  • Page 7 • This device is intended for single user only and should not be shared between users. • Do not drive while pumping. • Never use while pregnant, as pumping can induce labor. • Clean and sanitize all parts that come in contact with your breast and breast milk prior to first use.
  • Page 8: Cleaning Instructions

    • Never put breast pump motor in water or sterilizer, as permanent damage can be caused to the device. • DO NOT attempt to remove the breast shield from your breast while pumping. Turn the breast pump off and break the seal between your breast and breast shield with your finger, then remove the breast shield from your breast.
  • Page 9 5. Avoid using cloth towels to dry the pump parts because they can carry germs and bacteria that may contaminate the breast milk. 6. Once the pump parts are dry, assemble the pump before storage or use. 7. Try not to touch the inside of any parts that will come in contact with your breast milk.
  • Page 10 Assembling the Expression Collection Kit Pure Expressions comes pre-assembled, however you must reassemble the device after each cleaning. All parts of the device and accessories that come in contact with the breast milk, including the bottle, breast shield, membrane, and valve, should be cleaned and sterilized after each use.
  • Page 11 4. Connect two tubes to the Double-Connector (8) separately and connect the other end of the tubing to the Single-Connector (6). Then insert the Single-Connector into the hole of the breast shield. 5. Connect the Double-Connector to the Collector (10). (NOTE: For single-pumping use with one breast, disconnect one tube from the Double-Connector and insert...
  • Page 12: Device Operation

    Connecting the Expression Collection Kit and Pump Unit 1. Connect the Collector (10) to the pump’s air vent. 2. Attach the power cord to the pump unit. Then plug the A/C Adapter (12) into the wall socket outlet. Device Operation Wash hands before touching the breast pump, kit, and breasts.
  • Page 13 3. The Pure Expressions breast pump operates in two modes: Stimulation and Expression. Once the device is turned on, the timer will start and the pump will begin simultaneously in the Stimulation Mode at a fixed speed (88T/min) for two minutes. The device will then move to the Expression Mode at Suction Level 2 with Speed Level 1 (factory default).
  • Page 14 Guidelines for Storing and Thawing Breast milk You should store and thaw your breast milk correctly. This is the only way you can be sure that all the important nutrients are preserved and bacterial contamination is minimized. Check with your hospital for specific instructions. Breast Milk Storage (For Healthy Term Babies)* Freshly Expressed Thawed Breast Milk...
  • Page 15: Troubleshooting

    Tips for Freezing/Thawing Breast Milk: • Do not refreeze breast milk after thawing. • Never fill bottles/bags more than 3/4 to allow space for expansion. • Label the bottle/bag with the date you expressed the milk. • Do not store breast milk in the door of the refrigerator, store in the back of the main body of the refrigerator to avoid fluctuations in temperature.
  • Page 16: Warranty Information

    Warranty Information Limited Consumer Product Warranty (United States) This Drive Medical Electric Breast Pump is warranted to the original consumer “the purchaser” to be free from defects in material and workmanship which are not commercially acceptable for the period of one year from the date of purchase on the pump mechanism and a period of 120 days on all other components.
  • Page 17 In the event that this product if found by Drive Medical to not meet the above limited warranty, as purchaser’s sole and exclusive remedy, Drive Medical will repair or at the option of Drive Medical, replace this product without charge for such replacement parts or labor.
  • Page 18 E L E C T R I C B R E A S T P U M P Manufactured for: ©2017, Medical Depot Inc., DBA Drive Medical Design and Manufacturing 99 Seaview Blvd., Port Washington, NY 11050 All Rights Reserved. Made in China.

Table of Contents