FAX Class 1
Command
+FAE=
n
+FAR=
n
+FCL
= n
+FCLASS
= n
+FIT=
n,a
+FLO=
a
+FMI
+FMM
+FMR
+FPR=
n
+FRH=
n
+FRM=
n
+FRS=
n
+FTH=
n
+FTM=
n
+FTS=
n
Reference Guide
(Conexant)
Data/fax auto answer: 0=disable (default), 1=enable.
0=disable adaptive reception (default), 1=enable.
Set loss-of-carrier delay in units of 100 ms ( n =0 to 255).
Set active service class: 0=data mode (default), 1=Fax Class 1,
1.0=Fax Class 1.0 mode, 8=voice mode.
Set DTE inactivity timeout n seconds after which modem goes
on-hook ( a =0) or DCE goes on hook ( a =1).
Set flow control type: 0=XON/XOFF and RTS/CTS flow control
turned off; 1=XON/XOFF flow control in either direction; 2=RTS
for flow control of modem by DTE, and CTS for flow control of
DTE by modem.
Report modem manufacturer.
Report modem model.
Report modem version, revision, or date.
Set DTE/modem interface rate in bits/sec: 0=automatic
detection (default).
Receive data with HDLC framing.
Receive data.
Receive silence, n ×10 ms.
Transmit data with HDLC framing.
Transmit data.
Stop transmission and wait, n ×10 ms.
Reference Information