SolarEdge UL1741-SA Installation Manual

SolarEdge UL1741-SA Installation Manual

Single phase inverter with hdwave technology with setapp configuration
Table of Contents

Advertisement

Quick Links

Installation Guide
Single Phase Inverter with HD-
Wave Technology
with SetApp Configuration
For North America
Version 1.4

Advertisement

Table of Contents
loading

Summary of Contents for SolarEdge UL1741-SA

  • Page 1 Installation Guide Single Phase Inverter with HD- Wave Technology with SetApp Configuration For North America Version 1.4...
  • Page 2: Disclaimers

    The material furnished in this document is believed to be accurate and reliable. However, SolarEdge assumes no responsibility for the use of this material. SolarEdge reserves the right to make changes to the material at any time and without notice. You may refer to the SolarEdge web site (https://www.solaredge.com/us/) for the most...
  • Page 3: Fcc Compliance

    FCC Compliance FCC Compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 4: Revision History

    Revision History Revision History Version 1.4 (August 2020) Updated the communication board TCP details in Creating an Ethernet (LAN) Connection on page 53. Changed the cable type required for the RS485 and Ethernet connection to CAT6. Added the requirement for a special bracket, when installing close to the shoreline in Mounting the Inverter on page 32 Added a requirement to minimize the distance between the positive and negative DC optimizer cables in Step 3: Connecting Power Optimizers in Strings on page 23.
  • Page 5: Table Of Contents

    Disclaimers Important Notice FCC Compliance Revision History HANDLING AND SAFETY INSTRUCTIONS Safety Symbols Information IMPORTANT SAFETY INSTRUCTIONS Chapter 1: Introducing the SolarEdge Power Harvesting System Power Optimizer SolarEdge Inverter Monitoring Platform Supported AC Grids Installation Procedure Installation Equipment List Inverter Transport and Storage...
  • Page 6 Revision History Reporting and Monitoring Installation Data Designer Mapper Application Physical Layout Editor Using a Paper Template Chapter 6: Setting Up Communication to the Monitoring Platform Communication Options Communication Connectors Removing the Inverter Cover Removing the DC Safety Unit Cover (if applicable) Creating an Ethernet (LAN) Connection Creating an RS485 Bus Connection RS485 Bus Configuration...
  • Page 7: Handling And Safety Instructions

    HANDLING AND SAFETY INSTRUCTIONS HANDLING AND SAFETY INSTRUCTIONS During installation, testing and inspection, adherence to all the handling and safety instructions is mandatory. Failure to do so may result in injury or loss of life and damage to the equipment. Safety Symbols Information The following safety symbols are used in this document.
  • Page 8: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS CONSIGNES DE SÉCURITÉ IMPORTANTES CONSERVEZ CES INSTRUCTIONS WARNING! The inverter cover must be opened only after switching the inverter ON/OFF/P switch located at the bottom of the inverter to OFF. This disables the DC voltage inside the inverter. Wait five minutes before opening the cover. Otherwise, there is a risk of electric shock from energy stored in the capacitors.
  • Page 9 IMPORTANT SAFETY INSTRUCTIONS WARNING! The Safety Switch meets all requirements for a code-compliant installation of this system. The DC Disconnect Switch disconnects both the positive and negative conductors. AVERTISSEMENT! Le sectionneur externe (inclus) repond aux exigences de conformité pour l’installation de ce système . Le coupeur CC ouvre les conducteurs positifs et négatifs.
  • Page 10 State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov AVERTISSEMENT! Les produits SolarEdge peut vous exposer à des agents chimiques, y compris trioxyde d'antimoine, identifiés par l'État de Californie comme pouvant causer le cancer. Pour de plus amples informations, prière de consulter www.P65Warnings.ca.gov.
  • Page 11 IMPORTANT SAFETY INSTRUCTIONS NOTE A SolarEdge inverter may be installed in a site with a generator. SolarEdge requires installing a physical or electronic interlock, which will signal to the inverter when the grid has been disconnected. Interlock procurement, installation, maintenance and support are the responsibility of the installer.
  • Page 12: Chapter 1: Introducing The Solaredge Power Harvesting System

    Chapter 1: Introducing the SolarEdge Power Harvesting System The SolarEdge power harvesting solution maximizes the power output from any type of solar photovoltaic (PV) installation while reducing the average cost per watt. The following sections describe each of the system’s components.
  • Page 13: Solaredge Inverter

    (the SolarEdge monitoring platform; requires Internet connection). Monitoring Platform The monitoring platform enables monitoring the technical and financial performance of one or more SolarEdge sites. It provides past and present information on the system performance both at the system and module levels. Supported AC Grids The following figures illustrate grids that are supported by SolarEdge single phase inverters.
  • Page 14: Installation Procedure

    Figure 3: 208V AC grids supported by SolarEdge single phase inverter Installation Procedure The following is the procedure for installing and setting up a new SolarEdge site. Many of these also apply to modification of an existing site. Connecting Power Optimizers in...
  • Page 15: Inverter Transport And Storage

    Inverter Transport and Storage Appropriate mounting hardware (for example: stainless bolts, nuts, and washers) for attaching: the inverter mounting bracket to the mounting surface the power optimizer to the racking (not required for smart modules) Wire cutters Wire strippers Voltmeter Mobile phone with latest SetApp version For installing the communication options, you may also need the following: For Ethernet:...
  • Page 16: Chapter 2: Installing The Power Optimizers

    Chapter 2: Installing the Power Optimizers Chapter 2: Installing the Power Optimizers Safety The following notes and warnings apply when installing the power optimizers. Some of the following may not be applicable to smart modules: WARNING! The metallic enclosure of the power optimizer must be grounded in accordance with the product's listing and local and national codes.
  • Page 17 Le perçage de trous dans le cadre du module devra se faire suivant les instructions du fabricant. CAUTION! Installing a SolarEdge system without ensuring compatibility of the module connectors with the optimizer connectors may be unsafe and could cause functionality problems such as ground faults, resulting in inverter shut down. To ensure mechanical compatibility of the power optimizers’...
  • Page 18: Package Contents

    IMPORTANT SAFETY FEATURE Modules with SolarEdge power optimizers are safe. They carry only a low safety voltage before the inverter is turned ON. As long as the power optimizers are not connected to the inverter or the inverter is turned OFF, each power optimizer will output a safe voltage of 1V.
  • Page 19: Installation Guidelines

    For the minimum and maximum number of power optimizers in a string (string length), see the power optimizer datasheets. Refer to the Designer for string length verification. The Designer is available on the SolarEdge website at: https://www.solaredge.com/us/products/installer-tools/designer#/. The length of home-run cables from the first and last power optimizer to the inverter...
  • Page 20 Chapter 2: Installing the Power Optimizers If connecting more modules than power optimizer inputs in parallel, use a branch cable. Some commercial power optimizer models have a dual input. Position the power optimizer close enough to its module so that their cables can be connected.
  • Page 21: Step 1: Mounting And Grounding The Power Optimizers

    3. Attach each power optimizer to the rack using M6 (1/4'') stainless steel bolts, nuts and washers or other mounting hardware. Apply torque of 9-10 N*m / 6.5-7 lb*ft. For 3NA series power optimizes, SolarEdge recommends mounting the power optimizer on a rail with the smooth side facing out, so that the power optimizer body will prevent its rotation.
  • Page 22 (1) These methods have been evaluated by a nationally recognized testing laboratory as part of the optimizer evaluation. The SolarEdge-supplied grounding lug kit has been evaluated only for use with SolarEdge power optimizers. It is not intended or listed to be used as a general purpose grounding lug with other electrical equipment.
  • Page 23 Figure 6: Power optimizer installation and grounding using a grounding plate For mounting on un-grounded structures (such as a wooden structure): If the star washer or the plate cannot be used, use the SolarEdge grounding lug (purchased separately) with an equipment-grounding conductor according to the supplied instructions.
  • Page 24: Step 2: Connecting A Pv Module To A Power Optimizer

    Chapter 2: Installing the Power Optimizers 5. Verify that each power optimizer is securely attached to the module support structure. 6. Record power optimizer serial numbers and locations, as described in Reporting and Monitoring Installation Data on page 43. Step 2: Connecting a PV module to a Power Optimizer NOTE Images are for illustration purposes only.
  • Page 25: Step 4: Verifying Proper Power Optimizer Connection

    Step 4: Verifying Proper Power Optimizer Connection between the positive and negative DC cables. For detailed instructions, see: https://www.solaredge.com/sites/default/files/se-emi-performance- application-note.pdf. 3. Connect the rest of the power optimizers in the string in the same manner. WARNING! If using a dual-input power optimizer and some inputs are not used, seal the unused input connectors with the supplied pair of seals.
  • Page 26 Chapter 2: Installing the Power Optimizers In SolarEdge systems, due to the introduction of power optimizers between the PV modules and the inverter, the short circuit current I and the open circuit voltage V hold different meanings from those in traditional systems.
  • Page 27: Chapter 3: Installing The Inverter

    Identifying the Inverter Refer to the sticker on the inverter that specifies its Serial Number and its Electrical Ratings. Provide the serial number when contacting SolarEdge support. The serial number is also required when opening a new site in the monitoring platform.
  • Page 28: Inverter Interfaces

    Chapter 3: Installing the Inverter Inverter Interfaces The following figure shows the inverter connectors and components, located at the bottom of the inverter. Figure 10: Inverter Interfaces Communication gland: For connection of inverter communication options. Refer to Setting Up Communication to the Monitoring Platform on page 47 for more information.
  • Page 29 ), different system information, such as errors or performance indications. For more information, refer to https://www.solaredge.com/leds. (1) Blinking = Turns ON and OFF for the same duration (2) Flickering = Turns ON for 100 mS and turns OFF for 5 seconds (3) Alternating = alternate LED flashes Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 30 Chapter 3: Installing the Inverter The main LED indications are: Blue ON - the inverter is communicating with the monitoring platform Green ON - the system is producing Green blinking - AC is connected but the system is not producing Red ON - system error Figure 12: LEDs The following table describes system performance information by LED color and ON/OFF/P switch position.
  • Page 31: Opening Conduit Drill Guides

    Opening Conduit Drill Guides ON/ OFF/ LED Color Indication Comment Switch Green Blue Position Inverter configuration ON / P or reboot Inverter The upgrade firmware ON / P Alternating Alternating Alternating process can take upgrade up to 5 minutes Refer to Errors ON/ OFF/ ON/ OFF / Error...
  • Page 32 Chapter 3: Installing the Inverter Figure 13: Opening the Safety Switch cover 3. Remove the Safety Switch cover. 4. Open the required AC and DC conduit drill guides according to the conduits used in the installation: The drill guides are located at the bottom and sides of the enclosure, each with two sizes: ¾'' and 1''.
  • Page 33: Mounting The Inverter

    For SolarEdge inverters installed at a distance of 200 m / 655 ft. or closer to the shoreline, special brackets purchased separately from SolarEdge and SS304 stainless screws are required.
  • Page 34 Chapter 3: Installing the Inverter 2. To allow proper heat dissipation, maintain the following minimum clearance areas between the inverter and other objects: Figure 16: Clearance areas If installing a single inverter: 8" (20 cm) from the top of the inverter. At least 4"...
  • Page 35 Mounting the Inverter a. Lift the inverter from the sides, or hold it at the top and bottom of the inverter to lift the unit into place. Do not lift holding the Safety Switch as it may be damaged. b. Lower the inverter onto the U-shaped indentations, as shown below. Let the inverter lay flat against the wall or pole.
  • Page 36 Chapter 3: Installing the Inverter a. Mark the location of the bracket screw for the Safety Switch, and optionally the two additional bracket holes. Figure 18: Safety Switch bracket b. Remove the inverter from the wall/ pole. c. Drill the hole for the Safety Switch bracket. d.
  • Page 37: Chapter 4: Connecting The Ac And The Strings To The Safety Switch

    For systems with an integrated production and export/import meter: To install and activate the export/import metering function, refer to the document: https://www.solaredge.com/sites/default/files/se-inverters-with-rgm- and-export-import-meter-na.pdf The following figure illustrates the Safety Switch Figure 19: Inside the Safety Switch Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 38: Grid Connection Guidelines

    Use the conduit and wiring appropriate for the installation location per the NEC. Outdoor installations must use components that are rated NEMA 3R or higher. NOTE For more wiring information refer to the SolarEdge Recommended AC Wiring Application Note , available on the SolarEdge website at https://www.solaredge.com/sites/default/files/application-...
  • Page 39: Connecting The Strings To The Safety Switch

    Connecting the Strings to the Safety Switch Connecting the Strings to the Safety Switch You can connect systems with multiple DC strings in parallel to the DC input terminals of the Safety Switch. Inverters may have a different number of pairs of DC input terminals, depending on the inverter power rating.
  • Page 40 NOTE SolarEdge's fixed input voltage architecture enables the parallel strings to be of different lengths. Therefore, they do not need to have the same number of power optimizers, as long as the length of each string is within the permitted range.
  • Page 41: Chapter 5: Activating, Commissioning And Configuring The System

    Chapter 5: Activating, Commissioning and Configuring the System Chapter 5: Activating, Commissioning and Configuring the System You can connect communication options at this stage, as described in Setting Up Communication to the Monitoring Platform on page 47. After completing all connections, activate and commission the system using the inverter SetApp mobile application.
  • Page 42: Step 2: Commissioning And Configuring The Installation

    Chapter 5: Activating, Commissioning and Configuring the System 3. When the activation is complete, do one of the following: Select Connect to Another Device to continue activating additional inverters. Select Start Commissioning for pairing and other system configuration. Step 2: Commissioning and Configuring the Installation This section describes how to use the SetApp menus for commissioning and configuring the inverter settings.
  • Page 43 Refer to Setting Up Communication to the Monitoring Platform on page 47. Select Monitoring Communication to configure communication with the monitoring platform. Select Site Communication to configure communication between multiple SolarEdge devices or external non-SolarEdge devices, such as batteries or loggers. Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 44: Step 3: Verifying Proper Activation And Commissioning

    Reporting and Monitoring Installation Data Monitoring the site requires connecting the inverter to the monitoring platform, using any of the wired or wireless options available from SolarEdge. Refer to Setting Up Communication to the Monitoring Platform on page 47. Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 45 The monitoring platform includes a built-in help system, that guides you through the monitoring functionality. For more information, refer to https://www.solaredge.com/products/pv- monitoring#/. Creating Logical and Physical Layout using Installation Information To display a logical layout, insert the inverter serial number in the new site created in the monitoring platform.
  • Page 46: Designer

    You can create a project in Designer and export the site design with the string layout to the monitoring platform. For more information, refer to https://www.solaredge.com/products/installer-tools/designer#/. Mapper Application Use the Mapper smart phone application to scan the power optimizer and inverter 2D bar-codes and create a virtual map of a PV site for enhanced monitoring and easier maintenance.
  • Page 47: Using A Paper Template

    Once the form is completed, use the Mapper to scan the 2D codes and create the map in the monitoring platform. Optionally, you can send the sticker sheet to SolarEdge Support for physical layout creation. Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 48: Chapter 6: Setting Up Communication To The Monitoring Platform

    The following types of communication can be used to transfer the monitored information from the inverter to the monitoring platform. Only communication products offered by SolarEdge are supported. Ethernet Ethernet is used for a LAN connection. For connection instructions refer to Creating an Ethernet (LAN) Connection on page 53 Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 49 Communication Options RS485 RS485 is used for the connection of multiple SolarEdge devices on the same bus in a leader-follower configuration. RS485 can also be used as an interface to external devices, such as meters and third party data loggers.
  • Page 50: Communication Connectors

    Standard RJ45 terminal block for Ethernet connection RS485 connector 8-pin connector for power control devices The SolarEdge Wi-Fi antenna, ZigBee or Cellular Plug-ins can be connected to the communication board for optional wireless connection. Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 51 Communication Connectors Figure 22: Communication board connectors Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 52: Removing The Inverter Cover

    5. Open the inverter cover (see Figure 23 ). CAUTION! When removing the inverter cover, make sure not to damage the internal components. SolarEdge will not be held responsible for any components damaged as a result of incautious cover removal. ATTENTION! Lors du retrait du couvercle, assurez-vous de ne pas endommager les composants internes.
  • Page 53 Removing the DC Safety Unit Cover (if applicable) CAUTION! When removing the DC Safety Unit cover, make sure not to damage the internal components. SolarEdge will not be held responsible for any components damaged as a result of incautious cover removal. ATTENTION! Lors du retrait du couvercle, assurez-vous de ne pas endommager les composants internes.
  • Page 54: Creating An Ethernet (Lan) Connection

    For details refer to: https://www.solaredge.com/sites/default/files/overvoltage_ surge_protection_na.pdf. To connect the Ethernet cable: 1. Remove the inverter covers as described in Removing the Inverter Cover on page 51.
  • Page 55 Creating an Ethernet (LAN) Connection 3. Remove the plastic seal from one of the large openings. 4. Remove the rubber fitting from the gland and insert the CAT6 cable through the gland and through the gland opening in the inverter. 5.
  • Page 56 Chapter 6: Setting Up Communication to the Monitoring Platform Wire Color 10Base-T Signal RJ45 Pin # 100Base-TX Signal T568B T568A White/Brown White/Brown Reserved Brown Brown Reserved Figure 26: Standard cable wiring 7. Use a pre-crimped cable to connect via gland #1 to the RJ45 plug on the inverter's communication board or, if using a spool of cable, connect as follows: a.
  • Page 57: Creating An Rs485 Bus Connection

    You can connect more than one inverter to the same switch/router or to different switches/routers, as needed. Each inverter sends its monitored data independently to the SolarEdge monitoring platform. 10. The inverter is configured by default to LAN. If reconfiguration is required: a.
  • Page 58 If using a cable longer than 10 m/33 ft in areas where there is a risk of induced voltage surges by lightning, it is recommended to use external surge protection devices. For details refer to: https://www.solaredge.com/sites/default/files/overvoltage_ surge_protection_na.pdf. If grounded metal conduits are used for routing the communication wires, a lightning protection device is not required.
  • Page 59 Creating an RS485 Bus Connection Figure 28: RS485 terminal block on the communication board 4. Loosen the screws of pins A(+), B(-), and G on the left of the RS485 terminal block (RS485-1 ). Figure 29: RS485 terminal block 5. Insert the wire ends into the G, A and B pins shown above. Use Four- or six-wire twisted pair cable for this connection.
  • Page 60 9. Push the RS485 terminal block firmly all the way into the connector on the right side of the communication board. 10. Terminate the first and last SolarEdge device in the chain by switching a termination DIP-switch inside the inverter to ON (move the left switch up). The switch is located on the communication board and is marked SW2.
  • Page 61: Rs485 Bus Configuration

    4. From the Commissioning menu tap Site Communication. 5. Select the following to configure the connection: RS485-1 > Modbus (Multi-Device) RS485-1 > SolarEdge > SolarEdge Leader RS485-1 > Follower Detect The system starts automatic detection of the follower inverters connected to the leader inverter.
  • Page 62 Chapter 6: Setting Up Communication to the Monitoring Platform 3. Scroll down to the Communication section and check that the communication options are as required. Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 63: Appendix A: Errors And Troubleshooting

    Appendix A: Errors and Troubleshooting Appendix A: Errors and Troubleshooting This chapter describes general system problems, and how to troubleshoot them. For further assistance, contact SolarEdge Support. Identifying Errors Errors may be indicated in various system interfaces: On the inverter bottom panel, a red LED indicates an error.
  • Page 64: Troubleshooting Communication

    If after follower detection the number of followers displayed for the leader under RS485- > Follower Detect is lower than the actual number of followers, refer to the following application note to identify missing followers and troubleshoot connectivity problems: https://www.solaredge.com/sites/default/files/troubleshooting_ undetected_RS485_devices.pdf Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 65 3. Check that the selected communication option is properly configured. 4. Use a method independent of the SolarEdge device to check whether the network and modem are operating properly. For example, connect a laptop to the Ethernet router and connect to the Internet.
  • Page 66: Power Optimizer Troubleshooting

    Power Optimizer Troubleshooting Power Optimizer Troubleshooting Malfunction Possible Cause and Corrective Action Power optimizers are shaded. If you connected the inverter to the monitoring platform, retry pairing remotely (during Pairing failed sunlight). Make sure to leave the inverter ON/OFF/P switch ON and that S_OK appears in the status screen.
  • Page 67 ±1% par string est voltage. raisonnable. 3. Contact SolarEdge Support. Do not continue before finding the problem and replacing the malfunctioning power optimizer. If a malfunction cannot be bypassed or resolved, skip the malfunctioning power optimizer, thus connecting a shorter string.
  • Page 68: Appendix B: Mechanical Specifications

    Appendix B: Mechanical Specifications Appendix B: Mechanical Specifications The following figure provides inverter dimensions in mm [in]. Figure 32: SE10000H-SE11400H inverter dimensions Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 69: Appendix C: Replacing And Adding System Components

    Appendix C: Replacing and Adding System Components Appendix C: Replacing and Adding System Components This appendix includes replacement procedures for the SolarEdge system components. NOTE If you are permanently disassembling the installation or part of it, make sure to use the disposal methods dictated by local regulations.
  • Page 70 Replacing an Inverter Figure 33: Disconnecting the Safety Switch from the inverter 9. Remove the screws securing the inverter to the mounting brackets and lift the inverter from the mounting bracket. Figure 34: Mounting brackets Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 71: Replacing The Safety Switch

    Appendix C: Replacing and Adding System Components NOTE If you remove the old inverter and do not immediately install a new one, then: Lock the Safety Switch in the OFF position using a lock on the switch. Secure the Safety Switch bracket to the wall/pole, using 3 screws Use insulation tape to isolate each of the AC and DC wires.
  • Page 72: Adding, Removing, Or Replacing Power Optimizers

    Adding, Removing, or Replacing Power Optimizers 7. Open the Safety Switch bracket screws. Figure 35: Safety Switch bracket Disconnect the Safety Switch from the inverter by opening the two clips securing the Safety Switch to the inverter: Carefully place a screwdriver between the clip and the enclosure and pull the clip.
  • Page 73 6. In the monitoring platform, use the Replace button in the logical layout tab (in site Admin). Replace the serial number of the removed power optimizer with the serial number of the newly installed power optimizer. Refer to https://www.solaredge.com/sites/default/files/se- monitoring-portal-site-admin.pdf Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 74: Technical Specifications - Single Phase Inverters With Hd-Wave Technology (North America)

    48.5 Output Current @208V Max. output fault current 14 / 20 17.5 / 20 23 / 20 27.5 / 20 40 / 20 56.6 / 20 A / ms and duration @240V SolarEdge-Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 75 < 3% GFDI Threshold Utility Monitoring, Islanding Protection, Country Configurable Thresholds INPUT Maximum DC Power  4650 5900 7750 9300 11800 15500 17650 @240V (1) For other regional settings please contact SolarEdge support SolarEdge-Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 76 Maximum Inverter 99.2 Efficiency 99 @ 240V CEC Weighted Efficiency 98.5 @ 208V (1) A higher current source may be used; the inverter will limit its input current to the values stated SolarEdge-Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 77 17.7 x 14.6 x 6.8 / 450 x 370 x 174 in/mm Switch (HxWxD)  x 185 (1) Inverter with Revenue grade meter P/N: SExxxxH-US000BNC4; Inverter with Revenue grade and Export/Import meter P/N: SExxxxH-US000BNI4 SolarEdge-Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 78 -40 to +140 /-40 to +60 Range Protection Rating NEMA 4X (Inverter with Safety Switch) (1) Full power up to at least 50° C / 122° F. For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature- derating-note-na.pdf SolarEdge-Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 79: Recommended Ocpd Size Per Grid

    SE5000H-US 21 @ 240V 24 @ 208V 30 @ 208V SE6000H-US 25 @ 240V 35 @ 240V SE7600H-US SE10000H-US 48.5 @ 208V 70 @ 208V SE11400H-US 47.5 @ 240V 60 @ 240V SolarEdge-Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 80: Default Trip Limits And Times According To Ieee1547

    110% < V < 120% 1.00 V > 120 % 0.16 Frequency Range (Hz) Maximum Clearing Time (Sec) > 60.5 0.16 < 59.3 (Hawaii – 57) 0.16 (1) Time accuracy is +-30ms SolarEdge-Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4...
  • Page 81: Support Contact Information

    System configuration information, including the type and number of modules connected and the number and length of strings. The communication method to the SolarEdge server, if the site is connected. The product's software version as it appears in the status screen.

Table of Contents