Communication Connectors - SolarEdge StorEdge SE7600A-US1 Installation Manual

With backup
Table of Contents

Advertisement

Communication Connectors

The cellular kit can be purchased separately and assembled during system installation. 
The kit is provided with a user manual, which should be reviewed prior to connection. 
Refer to https://www.solaredge.com/sites/default/files/cellular_cdma_kit_installation_
guide_na.pdf.
Communication Connectors
Two communication glands are used for connection of the various communication options. Each gland 
has three openings. The table below describes the functionality of each opening.   U nused openings should 
remain sealed.
Gland#
Opening
One small
1 (PG16)
Two large
2 (PG13.5)
All three
The communication board has a standard RJ45 terminal block for Ethernet connection, and a 9-pin 
terminal block for RS485 connection,   a s shown below:
74
Functionality
External antenna cable
Ethernet connection (CAT5/6),
ZigBee, Cellular
RS485, power reduction
Figure 32: Communication Glands
Figure 33: Internal connectors
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.3
Cable Size (diameter)
2-4 mm
4.5-7 mm
2.5-5 mm