Do not use greater than 2 ampere battery charger to charge ignition backup battery.
(a) The battery may be charged using a 12 volt, 1 ampere battery charger.
(4) INSTALLATION
(a) Connect negative lead, the black heat shrink covered wire, to battery.
(b) Connect positive lead, the wire with white silicone tube over it, to battery.
(c) Place the battery in the mounting space.
(d) Place cover over battery and secure 4 quick turn fasteners.
(e) Reinstall right forward interior panel.
Manual number SSC10000AMM
Date: 04/18/2013
CUB CRAFTERS, INC.
CC11-160 MAINTENANCE MANUAL
NOTE
6.3.17
Page: 9