SERVICING

(1) DRAINING FUEL

The aircraft has two fuel drains, one under the fuselage and one on the fuel strainer,
located on the engine firewall.
Some aircraft (S/N 00264 and on) have a third fuel drain located on the bottom left
side of the fuselage, just aft of the firewall on the boot cowl.
Observe all precautions related to fueling and de-fueling the aircraft. In particular,
the following are highlighted:
Connect grounding wire to one of the wing tie-downs and ground the aircraft
to an earth ground.
Do not operate any electrical equipment during the de-fueling operation.
Operation of any electrical switch during the fueling operation is prohibited.
Do not allow smoking or open flames within 100 feet (of the aircraft or fuel
servicing vehicle are prohibited.
Do not operate radios, electric system, or electronic equipment during the
fueling or de-fueling operations.
Do not drain fuel tanks within 100 feet of any electrical equipment capable of
producing sparks.
Have a suitable fire extinguisher available at all times
(a) If your aircraft does not have the additional drain, jack the tail of the aircraft to
flight level attitude. (Section 6.3.2.1 & 6.3.2.2)
(b) Open the fuel strainer drain valve(s) and allow fuel to drain into container.
(c) If the fuel has been drained and the aircraft has then been re-fueled, the engine
must be run on the ground for enough time to purge the system of air prior to
flight.
6.3.15
Page: 2
CUB CRAFTERS, INC.
CC11-160 MAINTENANCE MANUAL
CAUTION
Manual number SSC10000AMM
Date: 04/18/2013