Combination Refrigerated Drinking Fountain (Cooler) and Bottle Filling Station delivers chilled, clean potable drinking water. Top Bottle Filling
section offer touchless activation to dispense water for bottles. While the bottom Water Cooler section, which houses the refrigeration and filtration
systems, delivers a steady stream of water for direct drinking at the press of front and sidebars.
Ratings
Electrical: 230Vac, 50Hz, (See Nameplate for Amperage), 1 phase.
Ambient Air Temperature: 10-38 °C (50-100.4 °F).
Water Pressure: 20-100 psig (0.14-0.69 MPa).
Maximum Water Temperature: 90 °F (32 °C).
Refrigerant: HFC-R134a
Definitions
DANGER
– Indicates death or serious injury will result if proper precautions are not taken.
WARNING
– Indicates death, serious injury or property damage can result if proper precautions are not taken.
CAUTION
– Indicates some injury or property damage may result if proper precautions are not taken.
Authorized Service Personnel – Factory trained personnel or personnel having working knowledge of electrical, plumbing and
machine (appliance) maintenance procedures.
Safety
DANGER
Please read these instructions completely before starting the installation or performing any service. Failure to follow the instructions and
safety precautions in this manual can result in serious injury or death.
After installation, keep these instructions in a safe location for future reference.
Electric supply must be identical in voltage, cycle, and phase to that specified on nameplate.
Electrical supply must have Ground Fault Circuit Interrupter (GFCI) protection.
A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules. This is
to allow electrical disconnection of the unit from electrical supply after installation.
WARNING
For use with clean, clear potable drinking water only. Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before the system.
Installation and connection to water and electrical mains must be in compliance with local and national laws.
All Installation and Service work must be performed by an authorized service personnel.
CAUTION
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental
capabilities or lack of experience and knowledge if they have been given supervision or instructions concerning use of the appliance
in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall
not be made by children without supervision.
To prevent a metallic taste or increased metal content in the water due to an electrolysis process caused by electrical feedback from
the grounding of electrical equipment to water supply and water waste mains, connect to these mains using non-conductive
materials. The provided Filter meets this requirement.
EZS8WS_2G, LZS8WS_2G, LZSDWS_2G
Installation / Use Manual
Original Instructions
Ingress Protection: IP2x
For Indoor Commercial Use only.
Water Inlet: 3/8"O.D. unplated copper tube.
Waste Water Outlet: 1-1/4" O.D. tube
Page 1
1000002684 (Rev. B - 09/18)

Advertisement

loading

Summary of Contents for Elkay EZS8WSVRL2K

  • Page 1 EZS8WS_2G, LZS8WS_2G, LZSDWS_2G Installation / Use Manual Original Instructions Model: LZS8WSS2K Bottle Filling Station & Cooler Description Combination Refrigerated Drinking Fountain (Cooler) and Bottle Filling Station delivers chilled, clean potable drinking water. Top Bottle Filling section offer touchless activation to dispense water for bottles. While the bottom Water Cooler section, which houses the refrigeration and filtration systems, delivers a steady stream of water for direct drinking at the press of front and sidebars.
  • Page 2: Installation

    EZS8WS_2G, LZS8WS_2G, LZSDWS_2G Installation For correct and safe installation, please read these instructions completely. DANGER • All Installation work must be performed by an authorized service personnel. • Disconnect electrical supply serving the Installation area to reduce risk of electrocution. •...
  • Page 3 EZS8WS_2G, LZS8WS_2G, LZSDWS_2G Rough-In: LZS8WSS2K 17 7/8" 454mm 7" 7" 178mm 178mm 7/16" X 3/4" OBROUND 3 9/16" (11mm X 19mm) HOLES (6) 90mm 6 3/8" 6 3/8" 18 7/8" ACTIVATION 162mm 162mm 479mm 15" SENSOR 381mm 19" 483mm HANGER BRACKET 9/32"...
  • Page 4: Operation: Start-Up

    EZS8WS_2G, LZS8WS_2G, LZSDWS_2G With the power cord, wire(s), and waterline through hole on top of water cooler place Bottle Filler on the WALL MOUNTING PLATE three (3) angled tabs protruding from the wall mounting plate, installed on wall (See Fig. 6). Make sure round boss in gasket fits in hole of basin.
  • Page 5 EZS8WS_2G, LZS8WS_2G, LZSDWS_2G Operation: Bottle Filler Control Board Set-Up BF11-BF12 VERIFY CONTROL BOARD SOFTWARE Continued from below: 1) To verify the software program of the control board the unit will 2) When the display changes to “SETTINGS”, depress the button again. need to be shut down and restarted.
  • Page 6: Service Adjustments

    EZS8WS_2G, LZS8WS_2G, LZSDWS_2G Service For proper and safe servicing, please read these instructions completely. DANGER • All Service and Maintenance must be performed by an authorized service personnel. • Disconnect electrical supply to the unit before any service work to reduce risk of electrocution. •...
  • Page 7 EZS8WS_2G, LZS8WS_2G, LZSDWS_2G Service: Inspection/Replacement • Inspect Bottle Filler and Cooler twice each year for proper operation and performance. • Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and reassembly and return to service practices. Lower Front Panel and Upper Shroud: To access the refrigeration system and plumbing connections, remove four (4) screws from bottom of cooler to remove the lower front shroud.
  • Page 8 REGULATOR ASSEMBLY ALIGNMENT NOTCH SNAP SNAP ALIGNMENT For Replacement Parts, contact your local distributor or call 1.800.834.4816 Elkay Manufacturing Co. 2222 Camden Court – Oak Brook, IL 60523 U.S.A – 630.574.8484 – www.elkay.com 1000002684 (Rev. B - 09/18) Page 8...

This manual is also suitable for:

Lzs8wss2k