6

Servicing and maintenance

6.1

General remarks

According to current legislation, the operator of an automatic door system is responsible for its main-
tenance and safety.
Accidents or defects can be avoided if the system operator takes good care of the system.
Testing
Type of test
Visual inspection
Mechanical inspection
Safety check (exit and es-
cape routes)
Function testing
Servicing
Type of servicing
Adjusting and cleaning
For documentation and information purposes, the testing and servicing work as well as the condition
of the system are recorded in a test log book. The test log book must be kept for at least one year or
until the next testing/servicing.
IMPORTANT
The testing and/or servicing interval according to the manufacturer's specification is at least 1
to 2 times a year.
IMPORTANT
The recommended and planned spare parts and wearing parts can be requested from your
service center.
6.2

Door care

The entire system, including the sensors and safety devices, can be cleaned with a moist cloth and
standard commercial cleaners (non-scouring, do not use any solvents). First test the cleaners on a
hidden (not easily visible) place. Keep all guides free of dirt.
NOTICE
It is recommended that for carrying out this work, the operating mode
ously open) be used, so as to avoid possible injuries from unwanted door movements.
BAL_C127-SU_OFFSET_EN_1V0_REC_121-006454770
Measure
Check door leaves, guides, bearings, limiting devices, sensors, and the securing of
crushing and shearing points for damage.
Check fastenings for tight fit.
Check sensors, safety devices, and monitoring devices for tight fit and damage.
Check functioning of switches, operators, controllers, power or energy storage
devices, and sensors.
Also check the adjustment of the safety devices and the setting of all movement se-
quences including the end points.
Measure
Clean and adjust bearings, sliding points, and power transmission.