5
Operation
5.5

Description of parameters

W = Factory settings: Basic drive (FP)
PARAMETER
DRIVING CYCLE
→ closing speed
→ Opening speed
TIME DELAY OPEN
→ time delay open
→ SSK time delay open
NOTICE
The open duration can be reduced when sensors are used which keep the door open, for ex-
ample Time delay.
OPERATOR
→ opening angle
24 / 32
W
REMARK
18
Speed when closing the door.
0 = lowest speed
40 = highest speed
– The maximum speed depends on the opening angle and accelera-
tion.
36
Driving speed of the opening door.
0 = lowest speed
40 = highest speed
– The maximum reachable speed depends on the driven distance
(door width) and the acceleration setting.
– DIN: >1.5 s <4 s
2
Determines how long the door remains open after it has been opened
by a trigger signal.
0..20 = 0 to 20 seconds, increment 1 s
21..40 = 22 to 60 seconds, increment 2 s
– The time delay open starts when all trigger and safety signals for
closing stop.
5
Determines the minimum time the door remains open after it has been
opened by a trigger signal of the type .
0..20 = 0 to 20 seconds, increment 1 s
21..40 = 22 to 60 seconds, increment 2 s
– The hold open time starts when all trigger and safety signals for
closing stop.
35
The opening angle is determined during the teach-in run and corres-
ponds to the value 40.
0 = minimum opening angle
40 = maximum opening angle
– DIN: min. 95°
BAL_C127-SU_OFFSET_EN_1V0_REC_121-006454770