Configuration C 127 Stg 127 V3_00_E - Record C 127 SU OFFSET User Manual

Table of Contents

Advertisement

System C 127 SU parameter overview
D = Value will reset after default parameter loading
S = Programming of slave 1 or slave 2
M = Parameter modification via MFT (key) on STG (technical level)
PARAMETER
Description
DRIVING CYCLE
Closing speed
└►
Opening speed
└►
Acceleration
└►
Latch check
└►
Force when closing
└►
TIME DELAY OPEN
Time delay open
└►
Time delay SSK
└►
DRIVE
Opening angle
└►
Collision close
└►
Collision open
└►
Brake
└►
Types of arms
└►
Inverse
└►
Spring type
└►
Limit open
└►
Momentum
└►
ENTRANCE SYSTEM
Measure A
└►
Measure G
└►
Fire alarm
└►
Control
└►
Interlock
└►
Door type
└►
MS 2-LEAVES
Function AKA
└►
Overlap
└►
Open sequence
└►
Close sequence
└►
MANUAL CONTROL
During closing
└►
When locked
└►
When one-way
└►
When automatic
└►
Collision
└►
Support during closing
└►
Active sensors
└►
Closing speed
└►
Opening assist
└►
CONTROL PANEL
BDE-M (mech. panel)
└►
BDE-D
└►
Language
└►
Keyboard
└►
Contrast BDE 1
└►
Contrast BDE 2
└►
Brightness BDE 1
└►
Brightness BDE 2
└►
Light time
└►
LOCKING
Locking function
└►
Lock type
└►
VRR manually
└►
Start delay
└►
CAN-BUS
(Units connected to CAN bus)
└►
INPUT/OUTPUT
STG
└►
AUX1_IN
└►
AKA_IN
└►
AKA_IN_F
└►
AUX1_OUT
└►
Sequential
└►
EMERG. STOP Reset
└►
MISCELLANEOUS
Push to actuate to open
└►
Alarm display
└►
Time activation
└►
Time safety
└►
Order number:
Programming by end customer / changes
This parameter overview shows all possible settings. Depending on drive type and configuration the access is restricted.
Parameter value (factory settings printed bold)
1
2
D S M
18
(Speedo)
D
36
(Speedo)
D
36
(Speedo)
D
M
0
(Speedo)
D
M
0
(Speedo)
D
M
2
(Speedo)
D
5
(Speedo)
D
35
(Speedo)
D S
20
(Speedo)
D S M
20
(Speedo)
D S M
S M
Without
Closed posit.
S M
Standard arm
Sliding pulling
M
Disabled
Enabled
S M
Unknown
EN 4
D S M
Disabled
Enabled
D S M
Disabled
Enabled
M
0
(Speedo)
M
0
(Speedo)
M
Disabled
Enabled
Master control
Single control
S M
Disabled
All operation
M
modes
USA
Basic operator
M
Airport
Default 1
Brussels
D
M
Master+slave
Master only
5
(Speedo)
D
M
5
(Speedo)
D
M
(Speedo)
D
M
15
D
M
Disabled
Enabled
D
M
Disabled
Enabled
D
M
Disabled
Enabled
D
M
Enabled
Disabled
D
M
Enabled
Disabled
Constant
Disabled
D
M
Final bang
Slow, final bang
stronger
stronger
D
M
Disabled
SIS disabled
D
M
20
(Speedo)
D
M
0
(Speedo)
4 Positions
3 Pos. (AUTO)
Manual;
Automatic;
Automatic;
Manual;
Cont. open;
Cont. open
Locked
D S
M
4 Positions
Automatic;
One-way;
Cont. open;
Locked
Deutsch
Français
M
Danish
Slovenscina
Türkçe
D
M
Normal
OFF-Mode
M
20
(Speedo)
M
20
(Speedo)
M
20
(Speedo)
M
20
(Speedo)
M
10
(Speedo)
Normally
1way locked
M
locked
M
Standard
Locking bolt
S M
Disabled
Enabled
M
0
(Speedo)
AKI 1
FEM 0... FEM 2
D
M
SI 2
AKA 2
D
M
Disabled
BEA Bodyguard
D
M
AKA
Railbeam
Inactive by 1way
D
M
Disabled
and locked
D
M
Disabled
BEA Bodyguard
D
M
Disabled
Seq. AKI / AKA
Disabled
Enabled
Normal
Disabled
D S M
(motored)
18
(Speedo)
D S M
18
(Speedo)
D S M
Client:
Date / Initials
STG 127
 Master
 Slave
3
4
DIN : > 1.5 s < 4 s
Different accelerations
Start latch check by closing
DIN : 0
DIN : min. 95°
Open posit.
Open/Clos. pos.
Sliding pushing
Inheader
EN 5
EN 6
Slave control
Master Interlock
Only one-way
/locked
US
EU
Low Energy
Low Energy
Nordics High
Nordics Low
0 = No overlap
0 = Simultaneous opening
0 = Simultaneous closing
Cumulative
Final bang
SIS enabled
SIS enabled AUTO
3 Pos.(OFF-A)
3 Pos. (OFF-M)
Automatic;
Manual;
OFF;
OFF;
Cont. open
Cont. open
English
English US
Polski
Magyar
40 = permanent lighting
Always locked
Magnet
Pulse
SI 1
AKA 1
SA 2
Closing button
Test sensors
Locked
Seq. AKI
Seq. SSK
Slow (motored)
≥ V3.00
5
6
Slave Interlock
UK
UK
Low Energy
Slowly,
Slowly,
cumulative
final bang
SIS without
3 Pos.(Lock-A)
3 Pos(Lock-M)
Automatic;
Manual;
Locked;
Locked;
Cont. open
Cont. open
Español
Nederlands
Italiano
Czech
SA 1
AKI 1
Closed
Gong