5

Operation

See also:
2 Configuration C 127 STG 127 V3_00_E [} 22]
2 Configuration FEM V1_10 with STG127 V2_40_E [} 23]
5.1

Control panel BDE-D

5.1.1

Operation modes and button functions

The buttons on the control panel BDE-D are used to set the door system operation modes in the main
menu. The parameters of the door system are set in the sub menu.
The button functions are divided into main menu and sub menu.
Main menu
Button
Name
Automatic button
Continuously open
button
One-way button
Locking button
Star button
Menu button
E
BAL_C127-SU_OFFSET_EN_1V0_REC_121-006454770
Operation
Press button 1 x
Press button 1 x
Press button 2 x or hold it
down for 2 seconds
Press button 1 x
Press button 1 x
Press button again
Press button 1 x
Press button 1 x
Restart control device:
press button for 5 seconds
Restart hardware BDE-D:
press button for 12 seconds
Function
Automatic operation via
sensors
For sliding door operator
and swing door operator:
continuously open, sensors
disabled
For sliding door operator:
manual operation
Passage only possible from
one direction
Door closed, sensors dis-
abled
The door opens again,
closes, and locks again.
Can be opened with a key
(optional).
For sliding door operator:
Reduced open width
For swing door operator:
manual operation
Access to parameter menu
Enable control lock
Restart control device
Restart hardware BDE-D
5
Operation
Display on LCD
Automatic
Continuously open
Manual
One-way
Locked
Locked
Automatic
Manual
19 / 32