Technical Data; Door Leaf Weights And Door Widths - Record C 127 SU OFFSET User Manual

Table of Contents

Advertisement

4

Technical Data

Dimensions:
Operating voltage:
Power consumption:
Max. torque:
Mass moment of inertia of door leaf:
Opening angle:
Time delay:
Opening speed:
Closing speed:
Noise emission:
Protection class:
Environmental conditions
Temperature range:
Humidity range:
Wind load:
4.1

Door leaf weights and door widths

The curves are calculated using the following formula:
Standard lever:
BAL_C127-SU_OFFSET_EN_1V0_REC_121-006454770
850 x 260 x 160 mm (stainless steel casing LxBxT)
230VAC, 50/60 Hz oder 115VAC, 50/60 Hz
Standby 13 W, rated power 67 W
80 Nm
140 kgm
Adjustable from 70° to 115°
Adjustable from 0 to 60 seconds (40 steps)
Adjustable from 3 to 20 seconds (40 steps)
Adjustable from 5 to 20 seconds (40 steps)
< 45 dB
IP67
-15° C to +50° C
Up to 85% relative humidity, non condensing
On request
2
J max. 140 kgm
2
2
J=1/3 x m x b
Key:
J = Mass moment of inertia kgm
m = Door leaf weight in kg
b = Door leaf width in m